Submittal Sheet
SK1691 SK1670
(1)
Required for basins over 72" (183 cm) deep (Square Guide Rail) and over 12' (3.7 m) (E-Z Out Rail). Allow for over-
head clearances.
(2)
Hardwire pump, float switch, and power supply inside junction box.
(3)
For square guide rail only
Note: Contact factory for control panel selection.
Note: Access doors available on field mount systems - consult factory.
Special basin configurations - consult factory.
© Copyright 2014 Zoeller
®
Co. All rights reserved.
502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | www.zoeller.com
PREPACKAGED AND JOB READY SYSTEMS
INDOOR
REQ. REQ.
1 Grinder (auto or nonauto) P/N _____________________ (A)
1 Alarm system (optional) P/N _____________________ (B)
1 Weight only
(required if alarm is used)
P/N 10-0689 (C)
1 Junction Box (optional)
P/N 10-0666 (E)
1 Basin, cover and hardware P/N _____________________ (F)
OUTDOOR
REQ. REQ.
1 Grinder (auto or nonauto) P/N _____________________ (A)
1 Control panel/alarm system P/N _____________________ (B)
1 Float switch(es) (if required) P/N _____________________ (C)
1 Weight(s) and bracket(s) P/N _____________________ (C)
1 Junction Box P/N _____________________ (E)
1 Basin, cover and rail system P/N _____________________ (G)
FIELD-MOUNT SYSTEMS
SIMPLEX
REQ. REQ.
1 Grinder (auto or nonauto) P/N _____________________ (A)
1 Alarm system (optional) P/N _____________________ (B)
1 Variable level float switch assembly
(2)
(not required for auto pumps) P/N _____________________ (C)
1 Weight and bracket only (2 required it alarm is used)
P/N 10-0661 (C)
1 Junction Box (optional) P/N _____________________ (E)
1 Rail system (optional) P/N _____________________ (H)
1 Angle arm/intermediate bracket
(1)
P/N _____________________ (H)
1 Pull rod
(3)
P/N _____________________ (J)
1 Stainless steel cable P/N _____________________ (K)
TYPICAL INDOOR SYSTEM (F)
TYPICAL OUTDOOR SYSTEM (G)
ON
(FIELD INSTALLED)
ALARM
4" RUBBER INLET
CAST IRON ADAPTERS
OFF
24" NOMINAL
TO ALARM PANEL
BALL VALVE
(FIELD INSTALLED)
GALVANIZED PIPE
1 1/4" X 32"
GALVANIZED PIPE
1 1/4" X 12"
GRINDER PUMP
SINGLE PHASE,2HP
1 1/4" GROMMET SEAL
(FIELD INSTALLED)
CAST IRON CHECK VALVE
1 1/4" FEMALE NPT
AUTOMATIC
36"
1 1/4" PVC SLIP X SLIP
PIPE SEAL
HIGH WATER ALARM
(FIELD INSTALLED)
ANTI-FLOTATION FLANGE
FIBERGLASS
CAST IRON CHECK VALVE
1 1/4" FEMALE NPT
DISCHARGE PIPE
1 1/4" GALVANIZED
24" MIN.
RECEPTACLE & ALARM
WATERTIGHT "QWIK BOX"
CONNECTIONS
SOLID FIBERGLASS COVER
1 1/4" PVC SLIP X SLIP
CAST IRON RAIL BASE PLATE
FIBERGLASS BASIN
"ON - OFF" FLOAT
PUMP CONTROL
CAST IRON MOUNT BRACKET
304 STAINLESS STEEL 16 GA.
1 1/2" SQ. GUIDE RAIL
BALL VALVE
PIPE AND FITTINGS
1 1/4" PVC SCH 40
STAINLESS STEEL FLOAT HOOK
STEEL LIFTING CABLE
1/8" 302 STAINLESS
DISCONNECT FITTING
1 1/4" NPT BRASS
STEEL PULL ROD
3/8" X 1' 416 STAINLESS
ALARM FLOAT
HIGH LEVEL
DISCHARGE FITTING
1 1/4" BULK HEAD
(FIELD INSTALLED)
4" RUBBER INLET PIPE SEAL
28" MIN. OR PER STATE
AND LOCAL CODES
COUPLING
TO CONTROL PANEL
HIGH WATER ALARM
(FIELD INSTALLED)
*60"
*OTHER BASIN SIZES
ARE READILY AVAILABLE