Product Overview
2
(C)
VARIABLE LEVEL FLOAT SWITCHES
P/N 10-0033* Switch without Weight &
Bracket for E820. WGT. 2.0
P/N 10-0748 Switch without Weight &
Bracket for I820. WGT. 2.0
P/N 10-0661 1 Weight & Bracket only.
WGT. 3.0
P/N 10-0689 1 Weight only. WGT. 2.5
P/N 10-1366 Set of Weights & Brackets.
Use with 10-0125/10-1037 and 10-1038.
WGT. 6.5
*Remove plug.
(D) CHECK VALVES
1¼" Cast Iron NPT Female
P/N 30-0163 WGT. 7.5
1½" Cast Iron NPT Female
P/N 30-0164 WGT. 7.5
2" Cast Iron NPT Female
P/N 30-0152 WGT. 10.0
P/N WGT. MODEL VOLTS PH MODE AMP
820-0011 89 WD820
*
230 1 Auto 13.7
820-0004 88 E820 230 1 Nonauto 13.7
820-0005 89 WH820
*
200 1 Auto 15.5
820-0006 88 I820 200 1 Nonauto 15.5
820 GRINDER
2 HP, 1¼" N.P.T.
VERTICAL DISCHARGE
* WD & WH grinder pumps are completely automatic with starting controls in pump switch case.
Note: 230V pumps are supplied with a 20 amp plug.
GRINDER SYSTEMS
(A)
© Copyright 2009 Zoeller Co. All rights reserved.
(E) JUNCTION BOXES (Contact factory if used in conjuction with a control panel)
OUTDOOR BASIN INSTALLATIONS
INDOOR BASIN INSTALLATIONS
INDOOR/OUTDOOR SYSTEM
STANDARD P/N 10-0623
DELUXE P/N 10-0682
(B) CONTROL PANELS & ALARM SYSTEMS
STANDARD FEATURES:
• Audible & Visual Alarm
• Alarm Silence Switch
• Test Switch for Alarm and Light
• UL Listed
Simplex Panels:
P/N 10-1037 Includes Alarm &
3 Floats for E820.
P/N 10-1038 Includes Alarm &
3 Floats for I820.
P/N 10-0125* Includes Alarm &
3 Floats for E or I Models.
Alarm Paks Only:
P/N 10-0053 Indoor only.
P/N 10-0623 Outdoor.
P/N 10-0126 Outdoor w/
Dry Alarm Contacts.
*Branch circuit protection provided by electrical installer.
SK1328
SK1330
INDOOR INSTALLATIONS
NEMA 1 P/N 10-1494
INDOOR/OUTDOOR SYSTEM
† NEMA 4X SIMPLEX CONTROL
PANEL WITH ALARM
† Low voltage terminal connector for fl oat switch.
WEIGHT
VARIABLE LEVEL
CORD
FLOAT SWITCH
BRACKET
FEMALE THREADS
BOTH ENDS
Qwik-Box Connection (For
use with WD Models only)
with Seals for (1) Power
Cord, (1) Pump Cord, and
(1) Alarm Switch Cord.
Alarm float switch must
operate on low voltage to
be used w/ Qwik Box.
P/N 10-0580 WGT. 3.0
4 Holes with Seals for (1) Pump Cord, (3)
Control Float Switch Cords and (1) Conduit
Connection, use with Control Panel/s (B).
P/N 10-0647 WGT. 2.5
4 Holes with Seals for (1) Pump Cord, (1)
Control Float, (1) Alarm Switch, and (1)
Conduit Connection for incoming power and
alarm return.
P/N 10-0677 WGT. 2.5
4 Holes with Seals for (1) Power Cord, (1)
Pump Cord, (1) Alarm Switch, & (1) Alarm
Return Feed.
P/N 10-0666 WGT. 2.5
SK2606
SK1628B
SK1628A
Note: All variable level fl oat switches in this
section are mechanically activated and do
not contain mercury.
(A) GRINDER MODEL 820
STANDARD FEATURES:
• 1¼" NPT Vertical discharge
• Carbon/Ceramic Seal
• Thermal Overload protection
• Engineered, glass-fi lled plastic impeller
with Stainless Steel insert
• Stainless Steel Cutter Plate/Cutter
• Stainless Steel Shaft
• Stainless Steel Hardware
• 20' Power Cord
OPTIONS:
Extra Length Cords (Consult Factory)