Specification Sheet

SECTION: 2.65.020
FM2806
1114
Supersedes
0814
TECHNICAL DATA SHEET
Battery Backup Pedestal Sump Pumps
PRODUCT SPECIFICATIONS
U
P
C
®
C
Complies with
ASME A112.3.4
and CSA B45.9.
Heavy duty 12V motor and positive contact float switch
Discharges water as fast as many 1/3 HP primary pumps
Minimum pit requirements: 18" x 22" (46 x 56 cm)
The complete Aquanot
®
II system includes the pump, the electronic
charger and a 12 V pump alarm. (You may purchase the deep-cycle
battery and battery box separately.)
Aquanot
®
II comes with these electronic charger features:
28.0 amp battery charger
LED status indicators
Automatic battery recharging
Microprocessor controlled
7.0 amp AC input
12 V DC output
Aquanot
®
Battery:
Size 31 “Wet” No. 10-0761 (69 lbs / 31 kg),
200-minute reserve capacity
Size 27 AGM” No. 10-1450 (66 lbs / 30 kg),
175-minute reserve capacity
Minimum battery requirements deep cycle,
size 27, 175-minute reserve capacity
SK1776
NOTE: This product is not intended for use as a primary water removal unit.
Product information presented
here reects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
®
Your Peace of Mind is Our Top Priority
®
© Copyright 2014 Zoeller Co. All rights reserved.
502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | www.zoeller.com