Installation Sheet
4
© Copyright 2016 Zoeller
®
Co. All rights reserved.
STEP 2 Float Stop Adjustment
2.1) Withthepumpinthepit,measurethedesiredoatstopon/offpositionsasshowninFig.2.1.Thesetwodimen-
sions will determine the on/off levels of the pump. The spacing between the upper and lower stops will determine
the amount of water removed from the pit.
Note: ItmaybenecessarytoraisetheoatrodguidetoadjustthestopstothedimensionsdeterminedinStep2.1.
CAUTION
The oat rod guide should NEVER be between the upper and lower stop.
2.2) Removethepumpfromthepitandadjusttheoatstopsasnecessary.Tightenallscrews.
Note: If a brick, or similar material has been used to raise the pump in the pit, it will be necessary to account for the
thickness of the brick.
Figure 2.2Figure 2.1
SK1776 SK1777
STEP 1 Placement of the Pump in the Pit
Note: Ifyourpithasacover,thenitwillhavetobemodiedtoacceptthe
Aquanot
®
.
1.1) Inspect the pit for debris and clean as necessary
1.2) Place the pump in the pit making certain that it is on a stable level
surface. Refer to Figure 1.1.
IMPORTANT: If this pump is to be used as a backup to your primary pump,
then make certain that there is no interference between the two pumps.
The motor is not watertight. It should NEVER bebelowoorlevel.
If necessary, bricks or similar materials, can be placed under the Aquanot
®
.
This product is meant to be used as a battery backup pump to
your primary pump only. Consult factory for advice before installing this unit
as a primary pump.
Figure 1.1
SK1775