Installation Sheet

4
© Copyright 2016 Zoeller
®
Co. All rights reserved.
STEP 2 Float Stop Adjustment
2.1) Withthepumpinthepit,measurethedesiredoatstopon/offpositionsasshowninFig.2.1.Thesetwodimen-
sions will determine the on/off levels of the pump. The spacing between the upper and lower stops will determine
the amount of water removed from the pit.
Note: ItmaybenecessarytoraisetheoatrodguidetoadjustthestopstothedimensionsdeterminedinStep2.1.
CAUTION
The oat rod guide should NEVER be between the upper and lower stop.
2.2) Removethepumpfromthepitandadjusttheoatstopsasnecessary.Tightenallscrews.
Note: If a brick, or similar material has been used to raise the pump in the pit, it will be necessary to account for the
thickness of the brick.
Figure 2.2Figure 2.1
SK1776 SK1777
STEP 1 Placement of the Pump in the Pit
Note: Ifyourpithasacover,thenitwillhavetobemodiedtoacceptthe
Aquanot
®
.
1.1) Inspect the pit for debris and clean as necessary
1.2) Place the pump in the pit making certain that it is on a stable level
surface. Refer to Figure 1.1.
IMPORTANT: If this pump is to be used as a backup to your primary pump,
then make certain that there is no interference between the two pumps.
The motor is not watertight. It should NEVER bebelowoorlevel.
If necessary, bricks or similar materials, can be placed under the Aquanot
®
.
This product is meant to be used as a battery backup pump to
your primary pump only. Consult factory for advice before installing this unit
as a primary pump.
Figure 1.1
SK1775