Spec Sheet
585
580
5 10 15 20 25 30 35
0
0
5
10
FLOW PER MINUTE
TOTAL DYNAMIC HEAD
15
20
GALLONS
LITERS
METERS
FEET
80
2
4
6
604020 100 120
40 5045
140
160 180
25
8
55
200
PUMP PERFORMANCE CURVE
MODEL 580/585
Productsmaynotbeexactlyasillustrated.Chargermayalsobepurchasedseparately.
PERFORMANCE DATA
The Aquanot
®
Series by Zoeller
For Primary Pump Backup & Emergency Use
ThecompleteAquanot
®
Isystemincludesthepump,thebattery
monitor,anda12Vpumpalarm.Youmaypurchasethedeep-cycle
batteryandbatteryboxseparately.
ThecompleteAquanot
®
IIsystemincludes
the pump, the electronic charger and a 12V
pumpalarm.Youmaypurchasethedeep-cycle
batteryandbatteryboxseparately.
Battery Monitor
Aquanot
®
I isdesignedtomaintainastanding
batteryatfullchargebytrickling1/2Amp.Itwill
notrechargeaspentbatteryafteralongpower
outage. A conventional battery charger must
be used to recharge the battery. The battery
monitorwillmaintainabatterychargeuntilyour
pumpisneeded.
Electronic Charger
Aquanot
®
II comeswiththesefeatures:
• 28ampbatterycharger
• LEDstatusindicators
• Automaticbatteryrecharging
• Microprocessorcontrolled
• Eachunitindividuallytested
• 7.0ampACinput;12VDCoutput
Aquanot
®
Battery
• Size31“Wet”No.10-0761(69lbs.)
200-minutereservecapacity
• Size27“AGM”No.10-1450(66lbs.)
175-minutereservecapacity
Min. battery requirements: deep-cycle, size 27,
175-minute reserve capacity.
Aquanot
®
II (Model 585)
Aquanot
®
I (model 580)
MINIMUM PIT
REQUIREMENTS
18” X 22”
SK1782
SK1781
011922
TOTAL DYNAMIC HEAD/CAPACITY
PER MINUTE
EFFLUENT AND DEWATERING
Aquanot
®
I Aquanot
®
II
MODEL 580 MODEL 585
FEET METERS GAL LTRS GAL LTRS
5 1.5 44 167 49 186
10 3.0 31 117 36 136
15 4.6 13 49 25 95
Shut-off Head 17 ft. (5.2 m) 20 ft. (6.1 m)
NOTE:Aquanot
®
II(Model585)datawasdeveloped
withthechargersupplyingDCpowertothepump.
©Copyright2013ZoellerCo.Allrightsreserved.
Aquanot
®
II electronic 28 Amp charger
(included w/ model 585)
Aquanot
®
deep-cycle battery
(purchase separately)
Aquanot
®
I
.5-amp
battery monitor
(included w/
model 580)
P/N10-1450-AGM
P/N10-0761-Wet(shown)
P/N10-0764-BatteryBox
CHECK VALVE
DRAIN TILE
(NOT INCLUDED)
BATTERY
GFCI OUTLET
BATTERY
MONITOR
ELECTRONIC
BASEMENT WALL
DISCHARGE
PRIMARY
PUMP
MAIN
LINE
CHECK VALVE