Installation Sheet

6
MODEL
ProPak
508-A
ProPak
508-B
ProPak
508-C
ITEM DESCRIPTION QTY
1/4
thru
6/15
6/15
thru
10/16
10/16
thru
Current
1 Pump, 12 V DC with terminals 1 152962 152962 152962
2 Battery box 1 10-0764 10-0764 10-0764
3 DC control charger with terminals 1 153000 153000 153000
4 “Off”/”On” oat switch 1 017197 017197 154438
5 Check valve (not shown) 1 019768 153772 153772
6 Hose coupling and clamps 1 019857 N/A N/A
7
Pump, M53/115 V (508-0006)
1
53-0001 53-0001 53-0001
Pump, M98/115 V (508-0007) 98-0001 98-0001 98-0001
8 1-1/2" PVC pipe tee 1 005645 153766 153766
9 1-1/2" X 2-1/8" long pipe 1 150197 N/A N/A
10 1-1/2" X 8-3/4" long pipe / sch 40 1 010619 019509 019509
11 Fuse, 30 Amp AGC 1 012353 012353 012353
CHECKLIST
EXPLODED VIEW - DC PUMP
All installations must comply with all applicable electrical and plumbing codes, including, but not limited to, National Electrical
Code, local, regional, and/or state plumbing codes, etc. Not intended for use in hazardous locations.
SK2961
BATTERY BOX
12 VOLT
MARINE BATTERY
SUPPLIED BY USER
FIG. 3
CLAMP
WHITE LEAD TO POSITIVE
BLACK LEAD
TO DC PUMP
WHITE LEAD
TO POSITIVE
BLACK LEAD
TO NEGATIVE
TO FLOAT
WHITE LEAD
30 AMP FUSE
DC CONTROL BOX
BLACK LEAD
TO NEGATIVE
TO FLOAT SWITCH
GREEN LEAD
SPLICER
FLOAT SWITCH
DC PUMP
FIGURE 3
© Copyright 2016 Zoeller
®