Brochure
© Copyright 2011 Zoeller Co. All rights reserved.
All installation of controls, protection devices and wiring should be done by a qualied licensed
electrician. All electrical and safety codes should be followed including the most recent National
Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).
For information on additional Zoeller products refer to catalog on SImplex Panels, FM1596; Piggyback
Variable Level Switches, FM0477; Electrical Alternator, FM0486; Mechanical Alternator, FM0495; Sump/
Sewage Basins, FM0487; Single Phase Alarm Systems, FM0732; Watertight Junctions Boxes, FM1597;
and Disconnect & Rail Systems, FM0787.
SELECTION GUIDE
1. Integral oat operated mechanical switch, no external control required.
2. For automatic use single piggyback variable level oat switch or double
piggyback variable level oat switch. Refer to FM0477.
3. See FM1228 for correct model of simplex control panel.
4. See FM0712 for correct model of duplex control panel or FM1663 for a
residential alternator system.
CONSULT FACTORY FOR SPECIAL APPLICATIONS
MODEL A B C D E F G H
266 4-3/4 8-5/16 6-13/32 4-3/4 6-15/32 2” NPT 14-1/32 6-3/32
267 4-3/4 8-5/16 6-13/32 4-3/4 6-15/32 2” NPT 14-9/32 6-11/32
268 4-3/4 8-13/32 6-13/32 4-3/4 6-15/32 2”/3” NPT 14-1/32 8-13/32
• Minimum recommended basin size (Small load applications)
Simplex - 18” x 30”
Duplex - 30” x 36”
• High water alarms available
RESERVE POWERED DESIGN
For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump.
SK375
267 MODELS Control Selection Listings
Model Volts-Ph Mode Amps Simplex Duplex CSA UL
M267 115 1 Auto 10.4 1 4 Y Y
BN267 115 1 Auto 10.4 ** 4 Y Y
N267 115 1 Non 10.4 2 or 3 2 or 4 Y Y
D267 230 1 Auto 5.5 1 --- Y Y
E267 230 1 Non 5.5 2 or 3 4 Y Y
** BE267 230 1 Auto 5.5 ** --- Y Y
* H267 200-208 1 Auto 6.2 1 --- Y N
* I267 200-208 1 Non 6.2 3 4 Y N
* J267 200-208 3 Non 2.6 3 4 Y Y
* F267 230 3 Non 2.6 3 4 Y Y
* G267 460 3 Non 1.5 3 4 Y N
**
268 MODELS Control Selection Listings
Model Volts-Ph Mode Amps Simplex Duplex CSA UL
M268 115 1 Auto 10.4 1 4 Y Y
** BN268 115 1 Auto 10.4 ** 4 Y Y
N268 115 1 Non 10.4 2 or 3 2 or 4 Y Y
D268 230 1 Auto 5.5 1 --- Y Y
E268 230 1 Non 5.5 2 or 3 4 Y Y
** BE268 230 1 Auto 5.5 ** --- Y Y
* H268 200-208 1 Auto 6.2 1 --- Y N
* I268 200-208 1 Non 6.2 3 4 Y N
* J268 200-208 3 Non 2.6 3 4 Y Y
* F268 230 3 Non 2.6 3 4 Y Y
* G268 460 3 Non 1.5 3 4 Y N
*No molded plug **Single piggyback switch included
266 MODELS Control Selection Listings
Model Volts-Ph Mode Amps Simplex Duplex CSA UL
M266 115 1 Auto 10.4 1 4 Y Y
** BN266 115 1 Auto 10.4 ** 4 Y Y
N266 115 1 Non 10.4 2 or 3 2 or 4 Y Y
D266 230 1 Auto 5.5 1 --- Y Y
E266 230 1 Non 5.5 2 or 3 4 Y Y
** BE266 230 1 Auto 5.5 ** --- Y Y
* H266 200-208 1 Auto 6.2 1 --- Y N
* I266 200-208 1 Non 6.2 3 4 Y N
* J266 200-208 3 Non 2.6 3 4 Y Y
* F266 230 3 Non 2.6 3 4 Y Y
* G266 460 3 Non 1.5 3 4 Y N
• For “M” and “D” models, the approximate gallons pumped out per cycle
are:
Tank Diameter Gallons Pumped
18” Simplex 8 Gallons
24” Simplex 15 Gallons
30” Duplex 22 Gallons
36” Duplex 33 Gallons
48” Duplex 60 Gallons
Caution: Maximum temperature of sewage or dewatering must be limited to
130°F (54°C). For over 130°F (54°C) special quotation required.
Standard All Models -
266 - Weight 41 lbs. ½ HP
267 - Weight 47.5 lbs. ½ HP
268 - Weight 51 lbs. ½ HP
TOTAL DYNAMIC HEAD
FLOW PER MINUTE
0 80 160 240 320 360 400
14012010080604020
0
5
10
2
4
15
6
20
25
LITERS
GALLONS
METERS
FEET
HEAD CAPACITY CURVE
266/267/268 MODELS
013225A
013225B
MODEL
Meters Liters
266/267/268
5 4841.5 128
10 3373.0 89
15 1894.6 50
20 386.1 10
Shut-off Head: 21.5 ft.(6.6m)
Feet Gal.
TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
SEWAGE AND DEWATERING