Brochure

© Copyright 2011 Zoeller Co. All rights reserved.
266 - 267 - 268 Series
(For Pump Prex Identication see News & Views 0052)
“WASTE-MATE”
SUBMERSIBLE
SEWAGE/*EFFLUENT PUMP
OR DEWATERING PUMP
2” NPT DISCHARGE
FEATURES AVAILABLE
Automatic
Nonautomatic (for variable level systems)
2” NPT Discharge (2” & 3” Model 268)
½ HP, 1 Ph, 115V, 200-208V, or 230V
Passes 2” Spherical Solids
BN and BE267 pumps available packaged with a
Piggyback Variable Level Float Switch
½ HP, 3 Ph, 200-208V, 230V, or 460V
Automatic
“267”
COMPARE THESE FEATURES
Float-operated, submersible (NEMA 6) 2-pole
mechanical switch
Durable cast construction, ASTM Class 25 cast
iron, switch case, and pump housing
Cast iron base on 267, 268
Engineered Plastic base on 266
Non-Clogging Vortex Impeller Design
Engineered plastic impeller with metal inserts
on models 266, 267 & 268 (1 PH) Model 267
available with cast iron impeller option (Cast iron
impeller standard on 3 PH models.)
Not effected by materials normally found in
drainage and sewage sumps
Stainless steel screws, bolts, handle, guard, and
arm and seal assembly
UL Listed 3-wire neoprene cord and plug
10 ft. cord standard for automatic
15 ft. cord standard for nonautomatic
Square Ring & Gasket - Neoprene
Motor - 266/267/268 Series - ½ HP 60 Hz, 1725
RPM, oil-lled, hermetically sealed, automatic
reset thermal overload protected (1 PH only)
Oil lubricated bearings
Carbon and ceramic shaft seal
Passes 2” spherical solids
2” NPT discharge
Model 268 contains combination 2” NPT female
and 3” NPT male discharge
On point - 12”; Off point - 4” (Automatic units)
Corrosion resistant powder coated epoxy nish
SECTION: 2.30.020
FM0390
1011
Supersedes
0311
Product information presented
here reects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
visit our web site:
www.zoeller.com
* May be used in those states where codes do not restrict solids size in
efuent systems.
** See back page for UL & CSA listings.
ALL MODELS ARE
COMPLETELY SUBMERSIBLE
HERMETICALLY SEALED
Watertight - dust tight.
Note: The sizing of efuent systems normally requires variable
level oat(s) controls and properly sized basins to
achieve required pumping cycles or dosing timers with
nonautomatic pumps.
Nonautomatic
“267”
for variable
level systems
Automatic
“268”
Tested to UL
Standard UL778
R
L
U
**
Certied to CSA
Standard C22.2 No.108
R