Installation Sheet
4
© Copyright 2017 Zoeller
®
Co. All rights reserved.
WD & WH MODEL INSTALLATION
WIRING DIAGRAM FOR MODELS
WD-230V,1Ph,60Hz.
WH-200/208V,1Ph,60Hz.
ModelsWD&WHarefullyautomatic.Aoatswitchisincludedand
factory-wiredinthepumpcircuittoprovideautomaticoperation
oncetheoatswitchissecuredproperlytotheoutletpipe.Use
thediagramabovetosecuretheoatswitchproperlyandobtain
thepropertethertocustomizetheon-offcycletoeachapplication.
Determining Pumping Range
in Inches (1 inch = 2.5 cm)
TetherLength 5 10 15 20 22
PumpingRange 9 13.5 18 22 24
max.
Useonlyasaguide.Duetoweightof
cable, pumping range above horizontal
isnotequaltopumpingrangebelow
horizontal. Ranges are based on testing in
nonturbulent conditions. Range may vary
due to water temperature and cord shape.
As tether length increases, so does the
variance of the pumping range.
min.
START
RUN
BLUE
MOTOR
(WHITE)
RED
(BROWN)
O.L.
YELLOW
(BLACK)
SWITCH
FLOAT
BLACK
BLACK
WHITE
CAPACITOR
BLUE
(1)
(2)
RED
RUN
WHITE
GREEN
L1
L2
(3)
011835
Note: Failuretokeepwithinpropertetherlimits
may prevent reliable switch operation.
Note: Cable must be mounted in horizontal
position.
22" MAX.
(559 mm)
5" MIN.
(127 mm)
20 AMP SWITCH (WD & WH MODELS)
SK305
THREE PHASE WIRING INSTRUCTIONS
FOR YOUR PROTECTION, ALWAYS
DISCONNECT PUMP FROM ITS POWER SOURCE
BEFORE HANDLING.
Toautomaticallyoperateanonautomaticthreephasepump,a
controlpanelisrequired.Followtheinstructionsprovidedwith
the panel to wire the system. For automatic three phase pumps,
see automatic 3 phase wiring diagram located to the far right.
Beforeinstallingapump,checkthepumprotationtoensurethat
wiring has been connected properly to power source, and that
thegreenleadofpowercord(seewiringdiagram)isconnected
to a valid ground. Momentarily energize the pump, observing the
directionsofkickbackduetostartingtorque.Rotationiscorrectif
kickbackisintheoppositedirectionofrotationarrowonthepump
casing. If rotation is not correct, switching of any two power leads
other than ground, should provide the proper rotation.
Allthreephasepumpsrequiremotorstartingdeviceswithmotor
overloadprotection.SeeFM0486forduplexinstallations.Pumps
mustbeinstalledinaccordancewiththeNationalElectricalCode
andallapplicablelocalcodesandordinances.Pumpsarenotto
beinstalledinlocationsclassiedashazardousinaccordance
withNationalElectricalCode,ANSI/NFPA70.
NONAUTOMATIC
3 PHASE
AUTOMATIC
3 PHASE
(3)
FLOAT
(1)
(2)
BLUE
TAN
COM
NC
CR
RELAY
7
8
B
ORANGE
A
1
2
3
4
(M1)
(M2)
9 6
4
5
WINDINGS
RED
YELLOW
PURPLE PURPLE
OR BROWN
BLACK
RED
WHITE
GREEN
L3L2L1
THERMOSTAT
WHITEWHITE
WHITE
RED
BLUE
013071
SINGLE PHASE WIRING INSTRUCTIONS
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. Single phase pumps
aresuppliedwitha3-pronggroundedplugtohelpprotectyouagainstthepossibilityofelectricalshock.DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE GROUND PIN.The3-prongplugmust beinsertedintoamating3-pronggroundedreceptacle.If the installation does not have such
areceptacle,itmustbechangedtothepropertype,wiredandgroundedinaccordancewiththeNationalElectricalCodeandallapplicablelocalcodes
and ordinances.
Risk of electrical shock. Do not remove power supply cord and strain relief or connect conduit directly to the pump.
Installationandcheckingofelectricalcircuitsandhardwareshouldbeperformedbyaqualiedlicensedelectrician.
Unitssuppliedwithoutaplug(singleandthreephase)andsinglephasenonautomaticunitswitha20ampplugmusthaveamotorcontrol
andliquidlevelcontrolprovidedattimeofinstallation.Thecontroldeviceshouldhavesuitablevoltage,ampere,frequency,groundingandhorsepower
rating for the pump to which it is connected.
IMPORTANT NOTICE: Someinsurancepolicies,bothcommercialandresidential,extendcoveragefordamagesincurredbyproductfailure.Youwillneedto
havepossessionoftheproducttosupportyourclaiminmostcases.ZoellerPumpCo.willexchangetheunitorrefundtheoriginalpurchasepriceoncetheclaim
is settled with the insurer in the case where you need to retain possession of the product to support a damage claim you submit to your insurance company.
006848
MOTOR
(3)
BLUE
RED
BLACK
GREEN/YELLOW
L1
L2
(1)
(2)
YELLOW
L3
GREY
BROWN
50 HZ
These are the original instructions.