Installation Sheet

2
© Copyright 2017 Zoeller
®
Co. All rights reserved.
with our products.
ContactManufacturerat,3649CaneRunRoad,Louisville,Kentucky40211,
Attention: Customer Support Department to obtain any needed repair or
replacementofpart(s)oradditionalinformationpertainingtoourwarranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED
OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR
A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED
TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty, so
theabovelimitationmaynotapplytoyou.Somestatesdonotallowtheexclusion
orlimitationofincidentalorconsequentialdamages,sotheabovelimitationor
exclusionmaynotapplytoyou.
Thiswarrantygivesyouspeciclegalrightsandyoumayalsohaveotherrights
which vary from state to state.
LIMITED WARRANTY
Manufacturerwarrants,tothepurchaserandsubsequentownerduringthewarranty
period,everynewproducttobefreefromdefectsinmaterialandworkmanship
under normal use and service, when properly used and maintained, for a period
ofoneyearfromdateofpurchase.Proofofpurchaseisrequired.Partsthatfail
within the warranty period that inspections determine to be defective in material
orworkmanshipwillberepaired,replacedorremanufacturedatManufacturer's
option, provided however, that by so doing we will not be obligated to replace
an entire assembly, the entire mechanism or the complete unit. No allowance
will be made for shipping charges, damages, labor or other charges that may
occur due to product failure, repair or replacement.
Thiswarrantydoesnotapplytoandthereshallbenowarrantyforanymaterial
or product that has been disassembled without prior approval of Manufacturer,
subjected to misuse, misapplication, neglect, alteration, accident or uncontrollable
act of nature; that has not been installed, operated or maintained in accordance
withManufacturer'sinstallationinstructions;thathasbeenexposedtooutside
substancesincludingbutnotlimitedtothefollowing:sand,gravel,cement,mud,
tar,hydrocarbons,hydrocarbonderivatives(oil,gasoline,solvents,etc.),orother
abrasive or corrosive substances, wash towels or feminine sanitary products,
etc.inallpumpingapplications.Thewarrantysetoutintheparagraphaboveis
inlieuofallotherwarrantiesexpressedorimplied;andwedonotauthorizeany
representative or other person to assume for us any other liability in connection
In those instances where damages are incurred as a result of an alleged pump failure,
the Homeowner must retain possession of the pump for investigation purposes.
CONDITION COMMON CAUSES
A. Pumpwillnotstartorrun.
Checkfuse,lowvoltage,overloadopen,openorincorrectwiring,openswitch,impellerorsealboundmechanically,motor
or wiring shorted. Float assembly held down. Switch, damaged or out of adjustment.
B.
Motor overheats and trips
overload or blows fuse.
Incorrectvoltage,negativehead(dischargeopenlowerthannormal)impellerorsealboundmechanically,motorshorted.
C. Pumpstartsandstopstoooften.
Floatswitchtetherlengthtooshort,checkvalvestuckopen,ornoneinstalledinlongdistanceline,overloadopen,bidding,
sump pit too small.
D. Pumpwillnotshutoff.
Debrisunderoatassembly,oatboundbybasinsidesorother,switch,damagedoroutofadjustment.
E.
Pumpoperatesbutdeliverslittle
or no water.
Checkinlet,strainerhousing,dischargepipe,andventholesforobstructions.Dischargeheadexceedspumpcapacity.
Loworincorrectvoltage.Incomingwatercontainingairorcausingairtoenterpumpingchamber.Incorrectmotorrotation.
(3phasepumpsonly)
F.
Drop in head and/or capacity
after a period of use.
Increasedpipefriction,cloggedlineorcheckvalve.Abrasivematerialandadversechemicalscouldpossiblydeteriorate
impellerandpumphousing.Checkline.Removebaseandinspect.
G. Tankorttingsleak.
Carefullytightenpipejoints(usepipedope)andscrews.Checkgasketlocation,tightenlidevenly.Donotovertighten
ttingsorscrews.
If the above checklist does not reveal the problem, consult the Product Support Department. Do not attempt to service or otherwise disassemble
pump. Service must be peformed by a Zoeller Authorized Service and Warranty Center. Visit www.zoeller.com for a complete list of service centers.
SERVICE CHECKLIST
DO’S & DON'T’S FOR INSTALLING UNIT
1. DO read all installation material with the unit.
2. DO inspect unit for any visible damage caused by shipping. Contact dealer
if unit appears to be damaged.
3. DOremovealldebrisfromthebasin.Besurethatthepumpwillhavea
hard, level surface beneath it. DO NOT install on sand, gravel or dirt.
4. DO be sure that the area is large enough to allow proper clearance for the
levelcontrolswitch(es)tooperateproperly.
5. DO Always Disconnect Pump From Power Source Before Handling.
DO always connect to a separately protected and properly grounded circuit.
DO NOT ever cut, splice, or damage power cord (Only splice in a watertight
junctionbox).
DO NOT carry or lift pump by its power cord.
DO NOTuseanextensioncord.
6. DOinstallacheckvalveandaunioninthedischargeline.
DO NOT use a discharge pipe smaller than the pump discharge.
7. DO NOTutilizethisunitforpumpinggasolineorotherhazardousliquids.
8. DO test pump immediately after installation to be sure the system is
workingproperly.
9. DO review all applicable governing codes and verify that the installation
conforms to each of them.
10. DOconsultmanufacturerforclaricationsorquestions.
11. DO
consideratwo-pumpsystemwithanalarmwhereaninstallationmaybecome
overloaded or primary pump failure would result in property damages.
12. DOconsideraD.C.BackupSystemwhereasumpordewateringpumpis
necessaryforthepreventionofpropertydamagesfromoodingduetoA.C.
power disruptions, mechanical or electrical problems or system overloading.
13. DO inspect and test system for proper operations at least every 3 months.