Submittal Sheet
084975
CAUTION
All installation of controls, protection devices and wiring should be done by a
qualified licensed electrician. All electrical and safety codes should be followed including the
most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).
TOTAL DYNAMIC HEAD
FLOW PER MINUTE
5
10
15
20
29.5ft (9m)
1.5
3.0
4.6
6.1
115V/60Hz
Model 201 - 60Hz
25 7.6
45 170.3
147.6
124.9
94.6
49.2
39
33
25
13
Qwik Jon Premier system includes the following three items:
(1) p/n 201-0006 Qwik Jon Premier grinder pump and tank.
(2) p/n 202-2000 Qwik Jon elongated toilet bowl.
(3) p/n 202-3002 Qwik Jon toilet tank and lid. An optional extension kit, p/n 10-3050 is available for recessed or behind-the-wall installations.
© Copyright 2021 Zoeller
®
Co. All rights reserved.
502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | zoellerpumps.com
5
10
15
20
29.5ft (9m)
1.5
3.0
4.6
6.1
115V/60Hz
Model 201 - 60Hz
25 7.6
45 170.3
147.6
124.9
94.6
49.2
39
33
25
13
When used with
1.28 gallon tank and
ll valve.
* Not IAPMO approved.
OPTIONS
• Complete the installation with a 1.28 gallon (4.8 L) per
ush EPA WaterSense listed, ADA compliant toilet with
an elongated bowl. Order P/N 202-3002 (toilet tank) and
P/N 202-2000 (toilet tank).
• Qwik Jon
®
extension kit, for behind-the-wall installations.
P/N 10-3050*
Model 202 meets the Americans with
Disabilities Act guidelines and ANSI A117.1
requirements for accessible and usable
facilities—check local codes.
SPECIFICATIONS
• Discharge can be reduced from 1" (DN25) to 3/4"
(DN 20) to replace existing systems
• Pumps any direction
• Shipping Weight: 31 lbs (14 kg)
• Check valve built into removeable discharge elbow
• Grinder Tank: (2) 1-1/2" (DN40) slip / 2" MPT auxilary inlets
and 1-1/2" (DN40) vent.
• Premium Tri-Slice (R) Cutter Technology: Investment-cast
440 stainless steel cutter and cutter plate is engineered
to handle cloth, latex, and other hard to grind materials.
ITEMS NEEDED BY INSTALLER
• Supply ttings and waste pipe
• Electrical source with ground fault
interrupter (GFCI) protected receptacle
• Water supply
• Tools
1 2
3 4
5
Plug the power cord into a wall socket to provide power to the unit.
QUICK REFERENCE GUIDE.
SEE INSTRUCTION MANUAL FOR
COMPLETE DE
084962 A
TAILS.
QWIK JON
®
PREMIER
MODEL #201
FIRE/EXPLOSION HAZARD.
Do not pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable
and/or explosive atmosphere. Failure to follow these warnings could result in death or serious injury and/or
property damage.
The Qwik Jon
®
Premier has an inlet on either side. This allows
for connections from other bathroom fixtures.
Connect the drain pipe from another bathroom fixture to the side
inlet on the Qwik Jon
®
Premier. The center of the side inlet needs
to be drilled out using a 1-3/4" (44 mm) hole saw. Ensure the
connections are in accordance with local, regional, and state
codes.
Connect the vent and discharge pipe to the top of the Qwik
Jon
®
Preimer.
Connect the rear discharge toilet to the front inlet of the Qwik
Jon
®
Premier. Ensure the connections are in accordance with
local, regional, and state codes.
https://www.zoellerpumps.com
© Copyright 2020 Zoeller
®
Co. All rights reserved.