MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE - TABLE 1
PIPE SIZE FLOW RATE
WATER
VELOCITY
PIPE SIZE FLOW RATE
WATER
VELOCITY
Inches MM GPM
Liter/
Min
Ft/sec
Meters/
sec
Inches MM GPM
Liter/
Min
Ft/sec
Meters/
sec
1.5” 50 50.76 192 6 2.44 2.5” 75 119.40 452 8 2.44
2” 63 83.65 317 8 2.44 3” 90 184.32 698 8 2.44
NOTE – No system should allow any higher than 8-ft/sec (2.44 meters/sec) water velocity. It is recommended
that a minimum length of piping, equivalent to 10 pipe diameters, be used between the pump suction inlet and
any plumbing ttings.
PUMP MOUNT MUST:
Allow pump inlet height to be as close to water level as possible.
Allow use of short, direct suction pipe (to reduce friction losses).
Allow for gate valves in suction and discharge piping.
Be protected from excess moisture and ooding.
Allow adequate access for servicing pump and piping.
Incorporate a straight portion of pipe prior to pump inlet no less than (5) pipe diameters in length.
Hazardous Pressure. Pumps, lters, and other equipment/components of a swimming
pool ltration system operate under pressure. Incorrectly installed and/or improperly
tested ltration equipment and/or components may fail resulting in injury and/or property damage.
PLUMBING
Use Teon tape to seal threaded connections on molded plastic components. All plastic ttings must be new
or thoroughly cleaned before use. NOTE - Do NOT use Plumbers Pipe Dope as it may cause cracking of
the plastic components. When applying Teon tape to plastic threads, wrap the entire threaded portion of
the male tting with one to two layers of tape. Wind the tape clockwise as you face the open end of the tting,
beginning at the end of the tting. The pump suction and outlet ports have molded-in thread stops. Do NOT
attempt to force hose connector tting past this stop. It is only necessary to tighten ttings enough to
prevent leakage. Tighten tting by hand and then use a tool to engage tting an additional 1 ½ turns. Use care
when using Teon tape as friction is reduced considerably; do NOT over-tighten tting or you may cause
damage. If leaks occur, remove connector, clean o󰀨 old Teon tape, re-wrap with one to two additional layers
of Teon tape, and re-install connector.
FITTINGS
Fittings restrict ow. For better e󰀩ciency, use the fewest possible ttings (but at least two suction outlets).
Avoid ttings that could cause an air trap. Pool and spa ttings MUST conform to the International Association
of Plumbing and Mechanical O󰀩cials (IAPMO) standards. Use a non-entrapping suction tting in pool (multiple
drains) or double suction (skimmer and main drain).