Product Overview
•Electricalalternators,forduplexsystems,areavailableandsuppliedwithanalarm.
•Mechanicalalternators,forduplexsystems,areavailablewithorwithoutalarms.
• Controlalarmsystemsareavailablefor1phasepumpsusedinsimplexsystem.SeeFM0732.
• Variablelevelcontrolswitchesareavailableforcontrollingsinglephasesystems.
• Doublepiggybackvariableleveloatswitchesareavailableforvariablelevellongcyclecontrols.
• SealedQwik-Boxavailableforoutdoorinstallations.SeeFM1420.
• RefertoFM0806forapplicationsabove130°F(54°C).
CONSULT FACTORY FOR SPECIAL APPLICATIONS
RESERVE POWERED DESIGN
ForunusualconditionsareservesafetyfactorisengineeredintothedesignofeveryZoellerpump.
Single Seal Design
Weight 43 lbs.
SELECTION GUIDE
1.Forautomaticusesinglepiggybackvariableleveloatswitchor
doublepiggybackvariableleveloatswitch.RefertoFM0477.
2.SeeFM1228forcorrectmodelofsimplexcontrolpanel.
3.SeeFM0712forcorrectmodelofduplexcontrolpanel.
CAUTION
All installation of controls, protection devices and wiring should
be done by a qualied licensed electrician. All electrical and
safety codes should be followed including the most recent
National Electric Code (NEC) and the Occupational Safety
and Health Act (OSHA).
© Copyright 2013 Zoeller Co. All rights reserved.
*Singlepiggybackswitchincluded.
SK1524A
Double Seal Design
Weight 63 lbs.
150090
3 7/8 6 5/16
4 5/8
3 29/32
4 5/32
12 13/32
1 1/2 - 11 1/2 NPT
16 1/8
4 5/32
3 29/32
4 5/8
6 5/163 7/8
1 1/2 - 11 1/2 NPT
SK1524B
25
20
15
10
0
0
6
4
2
30
8
METERS
FEET
GALLONS
LITERS
TOTAL DYNAMIC HEAD
FLOW PER MINUTE
10 20 30 40 50 60 70 80 90
80 160 240 320
10
12
14
35
40
45
75
5
PUMP PERFORMANCE CURVE
MODEL 140/4140/145/4145
50
16
18
20
22
70
65
60
55
140/
4140
145/
4145
TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
EFFLUENT AND DEWATERING
MODEL
Meters
Shut-off Head:
140/4140
Feet Gal. Liters
326861.55
10 3.0 80 303
15 4.6 73 276
20 6.1 66 250
25 7.6 59 223
30 9.1 49 185
40 12.2 28 106
50 ft.(15.2m)
145/4145
Gal. Liters
50
60
15.2
18.3
--
--
--
--
74 ft.(22.6m)
61
60
56
53
49
45
35
26
16
232
228
213
201
186
171
133
99
61
140/4140 & 145/4145 MODELS - SINGLE PHASE Control Selection
Model Model Volts Mode Amps Simplex Duplex
N140 N4140 115 Non 12 1or2 3
E140 E4140 230 Non 6 1or2 3
BN140 BN4140 115 Auto 12
*
---
BE140 BE4140 230 Auto 6
*
---
N145 N4145 115 Non 13 1or2 3
E145 E4145 230 Non 6 1or2 3
BN145 BN4145 115 Auto 13
*
---
BE145 BE4145 230 Auto 6
*
---