Spec Sheet
TYPICAL INSTALLATIONS
© Copyright 2013 Zoeller Co. All rights reserved.
SK305A
PUMP PLUG
SWITCH PLUG
AUTOMATIC
OPERATION
MANUAL
OPERATION
SK308A
SK308
PIGGYBACK VARIABLE LEVEL FLOAT SWITCH
RECOMMENDATIONS FOR ZOELLER COMPANY PUMPS
SWITCH
MODEL
NO.
SWITCH SPECIFICATIONS
PUMPING
RANGE
USE WITH ZOELLER PUMP MODEL NUMBERS
10-0055
10'Cord,SinglePiggyback
115V,1PH,13A
6"Min.
36"Max.
"N"Models-53,55,57,59,98,137,139,140,264,266,267,268&282(SeeNote2).
10-0034
15'Cord,SinglePiggyback
115V,1PH,13AMax.
10-0063
20'Cord,SinglePiggyback
115V,1PH,13A
10-0032
15'Cord,SinglePiggyback
115V,1PH,15A
6"Min.
36"Max.
"N"Models-161,163,270&292(SeeNote2).
10-0705
20'Cord,SinglePiggyback
115V,1PH,15A
10-1964
15'Cord,DoublePiggyback
115V,1PH,13A
3"Min.
48"Max.
"N"Models-53,55,57,59,98,137,139,140,264,266,267,268,&282(SeeNote2).
10-0035
15'Cord,SinglePiggyback
230V,1PH,13A
6"Min.
36"Max.
"E"Models-53,55,57,59,98,137,139,140,161,163,165,185,264,266,267,268,270,282,
284&293(SeeNote2).
"I"Models-137,139,161,163,165,185,266,267,268,282,284,293(SeeNote2).
10-0706
20'Cord,SinglePiggyback
230V,1PH,13A
10-0033
15'Cord,SinglePiggyback
230V,1PH,15A
6"Min.
36"Max.
"E"Models-186,188,294,404&820(SeeNote2).
"I"Model-404.
10-0559
20'Cord,SinglePiggyback
230V,1PH,15A
10-1965
15'Cord,DoublePiggyback
230V,1PH,13A
3"Min.
48"Max.
"E"Models-53,55,57,59,98,137,139,140,161,163,165,185,264,266,267,268,270,282,
284&293(SeeNote2).
"I"Models-137,139,161,163,165,185,266,267,268,282,284&293(SeeNote2).
10-0748
25'Cord,WiredinPump
Switch115Vor230V,
1PH,20A(SeeNote3).
9"Min.
24"Max.
"E"Models-189,295&405(SeeNote2).
"I"Models-188,189,294,295,405&820(SeeNote2).
Notes:
1) "I"models-188,189,294,295,405usethesinglepiggybacktypeonlywitha10-0125Simplex
PumpControlBox.
2) Removeplugifpresentandusewith"JunctionBox"10-0002wheneldwiringisrequired.
3) Maximumoperatingtemperaturefor10-0748-120°F(49°C);allotherswitches-140°F(60°C).
4) ForDuplexSystems,usewithappropriatepanel(SeeFM0712).ForSimplexSystems,usewith
appropriatepanel(SeeFM1228).
CAUTION
All installation of controls, protection devices and wiring should be done by a qualied
licensed electrician. All electrical and safety codes should be followed including the most
recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).
SINGLE
PIGGYBACK
DOUBLE
PIGGYBACK
CORDS SECURED
"ON"
"OFF"
LEVEL
LEVEL
TO DISCHARGE
PIPE
RANGE
PUMPING
FLOAT
CLAMPS
THE "ON" LEVEL IS
APPROXIMATELY 4"
ABOVE MOUNTING
LOCATION
THE "OFF" LEVEL IS
APPROXIMATELY 4"
BELOW MOUNTING
LOCATION
MECHANICAL FLOAT SWITCH
10-1964, 10-1965, 10-1966, 10-1967