Product Overview
TYPICAL INSTALLATIONS
© Copyright 2007 Zoeller Co. All rights reserved.
DISCHARGE PIPE
CORDS SECURED TO
LEVEL
"OFF"
LEVEL
"ON"
TETHER LENGTH
PUMPING RANGE
SK305A
PUMP PLUG
SWITCH PLUG
AUTOMATIC
OPERATION
MANUAL
OPERATION
SK308A
CORDS SECURED
"ON"
"OFF"
LEVEL
LEVEL
TO DISCHARGE
PIPE
ON TOP
GRAY FLOAT
FLOAT
CLAMPS
RANGE
PUMPING
1 TO 48 INCHES
SK308B
ZOELLER PIGGYBACK VARIABLE LEVEL FLOAT SWITCH
RECOMMENDATIONS FOR ZOELLER PUMP COMPANY PUMPS
SWITCH
MODEL
NO.
SWITCH SPECIFICATIONS
PUMP-
ING
RANGE
USE WITH ZOELLER PUMP MODEL NUMBERS
10-0055
10' Cord, Single Piggyback
115V, 1 PH, 13A
6" Min.
36" Max.
"N" Models - 53, 55, 57, 59, 98, 137, 139, 140, 264, 266, 267, 268 & 282 (See Note 2).
10-0034
15' Cord, Single Piggyback
115V, 1 PH, 13A Max.
10-0063
20' Cord, Single Piggyback
115V, 1 PH, 13A
10-0032
15' Cord, Single Piggyback
115V, 1 PH, 15A
6" Min.
36" Max.
"N" Models - 161, 163, 270 & 292 (See Note 2).
10-0705
20' Cord, Single Piggyback
115V, 1 PH, 15A
10-1964
15' Cord, Double Piggyback
115V, 1 PH, 13A
1" Min.
48" Max.
"N" Models - 53, 55, 57, 59, 98, 137, 139, 140, 264, 266, 267, 268, & 282 (See Note 2).
10-0035
15' Cord, Single Piggyback
230V, 1 PH, 13A
6" Min.
36" Max.
"E" Models - 53, 55, 57, 59, 98, 137, 139, 140, 161, 163, 165, 185, 264, 266, 267, 268, 270, 282,
284 & 293 (See Note 2).
"I" Models - 137, 139, 161, 163, 165, 185, 266, 267, 268, 282, 284, 293 (See Note 2).
10-0706
20' Cord, Single Piggyback
230V, 1 PH, 13A
10-0033
15' Cord, Single Piggyback
230V, 1 PH, 15A
6" Min.
36" Max.
"E" Models - 186, 188, 294, 404 & 820 (See Note 2).
"I" Model - 404.
10-0559
20' Cord, Single Piggyback
230V, 1 PH, 15A
10-1965
15' Cord, Double Piggyback
230V, 1 PH, 13A
1" Min.
48" Max.
"E" Models - 53, 55, 57, 59, 98, 137, 139, 140, 161, 163, 165, 185, 264, 266, 267, 268, 270, 282,
284 & 293 (See Note 2).
"I" Models - 137, 139, 161, 163, 165, 185, 266, 267, 268, 282, 284 & 293 (See Note 2).
10-0748
25' Cord, Wired in Pump
Switch 115V or 230V,
1 PH, 20A (See Note 3).
9" Min.
24" Max.
"E" Models - 189, 295 & 405 (See Note 2).
"I" Models - 188, 189, 294, 295, 405 & 820 (See Note 2).
Notes:
1) "I" models -188, 189, 294, 295, 405 use the single piggyback type only with a 10-0125 Simplex
Pump Control Box.
2) Remove plug if present and use with "Junction Box" 10-0002 when fi eld wiring is required.
3) Maximum operating temperature for 10-0748 - 120°F (49°C); all other switches - 140°F (60°C).
4) For Duplex Systems, use with appropriate panel (See FM0712). For Simplex Systems, use with
appropriate panel (See FM1228).
All installation of controls, protection devices and wiring should be done by a qualifi ed
licensed electrician. All electrical and safety codes should be followed including the
most recent National Electrical Code (NEC) and the Occupational Safety and Health
Act (OSHA).
SINGLE