Install Instructions

5
© Copyright 2010 Zoeller Co. All rights reserved.
Qwik Jon
®
Ultima Qwik Reference Guide
STEP 1 Location Selection
Plan your new installation carefully.
Floor: The oor should be structurally sound
and level within 1/8". If the oor is not level,
use hydraulic cement or similar material to
level the oor.
Water: A water supply will be needed to operate
the toilet. Usually a 1/2" line with a shut-off
valve is suf cient.
Electrical: A 115 volt GFCI receptacle will
be needed to supply electrical power to the
pump.
Sewage: Access to a sewage line is required.
The Qwik Jon
®
Ultima requires a 1" (or 3/4" if
your codes permit) sewage discharge line to
connect to an existing sewage line. A ball or
gate valve should be installed in the discharge
line.
Vent: Access to a vent pipe is required. The
use of a mechanical vent system is NOT
recommended as the toilet will not ush.
NOTE: If a built-in installation is to be used,
locate the pump unit in an area that will allow
access to the pump and switch.
GFCI
OUTLET
WATER
SUPPLY
DISCHARGE
PIPE
VENT
PIPE
LEVEL FLOOR
BALL OR GATE VALVE
SOLD SEPARATELY.
SK2588
STEP 2 Leveling of Pump Unit
Do not use wooden shims to level the pump unit!
Ensure that nails, screws or other sharp objects do
not puncture the pump unit!
Level the pump unit to within 1/8" using hydraulic cement or
similar material.
SK2589