Install Instructions

QWIK JON
®
ULTIMA 202 SYSTEMS
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST
1. To help reduce the risk of elec tri cal shock, a properly
ground ed re cep tacle or con trol box of grounding type must
be in stalled and pro tect ed by a ground fault circuit interrupter
(GFCI) in ac cor dance with the Na tion al Electrical Code and
applicable local codes. Never re move ground pin from
plug.
2. Make certain that the ground fault in ter rupt er protected
re cep tacle is with in reach of the pump’s power supply cord. DO
NOT USE AN EXTENSION CORD. Ex ten sion cords that are
too long or too light do not deliver suf cient voltage to the pump
motor. But more im por tant, they could present a safety hazard
if the insulation were to become damaged or the con nec tion
end were to fall into a damp or wet area.
3. Make sure the pump's elec tri cal sup ply cir cuit is equipped
with fuses or circuit break ers of prop er capacity. A sep a rate
branch circuit, sized ac cord ing to the National Electrical Code
for the current shown on the pump name plate is recommended
(see Note 3).
4. TESTING FOR GROUND. As a safe ty mea sure, each elec tri cal
outlet should be checked for ground using an Un der writ ers
Lab o ra to ry Listed cir cuit an a lyz er which will indicate if the
power, neutral and ground wires are cor rect ly con nected to your
outlet. If they are not, call a quali ed licensed electrician.
5. FOR YOUR PRO TEC TION ALWAYS DIS CON NECT PUMP
FROM ITS POW ER SOURCE BE FORE HAN DLING. If pump
is wired direct, de-energize the circuit at the control box.
Ground ed pumps are supplied with a 3-prong grounded plug
to help protect you against the possibility of elec tri cal shock.
DO NOT UNDER ANY CIRCUM STANCES RE MOVE THE
GROUND PIN. To re duce the risk of elec tri cal shock, a properly
grounded receptacle of grounding type must be installed
and protected by a ground fault circuit interrupter (GFCI) in
ac cor dance with National Elec tri cal Code and ap pli ca ble local
codes.
6. Installation and checking of elec tri cal cir cuits and hard ware
should only be performed by a qual i ed li censed electrician.
7. According to the state of California (Prop 65), this product
contains chemicals known to the state of California to cause
cancer and birth defects or other reproductive harm.
NOTICE TO INSTALLER: Instructions must remain with installation.
SECTION: 6.10.063
FM2369
0410
Supersedes
0310
P/N 018507
© Copyright 2010 Zoeller Co. All rights reserved.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
visit our web site:
www.zoeller.com
1. Inspect all materials. Oc ca sion ally, products are damaged dur ing ship ment. If the unit is damaged, contact your dealer be fore
using. Do Not remove the test plugs from the pump.
2. Carefully read all the lit era ture pro vid ed to fa mil iar ize your self with speci c details re gard ing in stal la tion and use be fore
at tempt ing the in stal la tion. These ma te ri als should be retained for future reference.
1. This unit is not designed to handle any material other than
human waste and toilet paper. The following list includes, but
is not limited to, items that should not be used with this system:
Feminine sanitary products, condoms, cotton balls and swabs,
baby wipes, paper towels, etc.
2. Check to be sure your power source is ad e quate to handle the
am per age requirements of the motor as indicated on the pump
or unit I.D. tag.
3. All plumbing (discharge and vent lines) must be installed to meet
local codes. Unit must be vent ed. Do not use an automatic
plumbing vent device. Toilet will not ush.
4. Maximum operating tem pera ture for model 202 must not exceed
130°F (54°C).
5. Do not use cleaning products containing bleach in the toilet
tank, toilet or attached xtures as they will degrade the pump
seals.
1. Repair and service should be performed by an Authorized
Service Station only. (Consult Factory.)
2. NOTE: Recommended for installations up to 20' total dynamic
head. Consult Factory if installation is above 15' vertical height
in 1" pipe. Mini-Grinder Pump is de signed for use in Qwik
Jon
®
Ultima units only. It is not designed for use in any other
application.
3. Mini-grinder pump is rated for 115V, 60 Hz, 7 Amps, .5 HP.
4. NOTE: Pumps with the “UL” mark and pumps with the “US”
mark are tested to UL Standard UL778. CSA Certi ed pumps
are certi ed to CSA Standard C22.2 No. 108.Qwik Jon
®
Ultima
units only. It is not designed for use in any other application.
5. Model 202 toilet utilizes 1.6 gallons per ush.
6. All xtures connecting to the system must be on the same oor
level.
Product information presented
here re ects con di tions at time
of publication. Consult factory
re gard ing dis crep an cies or
in con sis ten cies.
MODEL NO. ____________________
DATE CODE: __________________
DATE INSTALLED: _____________
SEE BELOW FOR LIST OF NOTES
NOTES
REFER TO WARRANTY ON PAGE 2.
SEE BELOW FOR LIST OF WARNINGS
SEE BELOW FOR LIST OF CAUTIONS
Patent No. 7,203,976
Other Patents Pending