Instruction manual

8 9
Afterinstallationit’srecommendedtheacidpumpbetestedandtheacid
pump‘primed’.
WARNING!Beforetestingthepump,ensureallacidsupplyanddelivery
connectionsaresecure.Alwaysuseappropriatesafetyequipmentwhen
handlingacid.
TotesttheAcidPump:
1. Pressthe
button.
2. Press
/ buttonstomovearrowto‘pHSETUP’.
3. Press
toenterthe‘pHSETUP’menu.
4. Usethe
/ buttonstohighlight‘TESTACID’andpress to
entertestacidmenu.
5. Awarningwillmomentarilybedisplayed,thenpress
againto
startthepump.
Theacidpumpwillrunforapproximately10minutesandautomatically
switchoff.(Ifthepumpneedstobeturnedoffimmediately,pressthe
button)
NOTE:Steps1to5mayrequirerepeatingseveraltimesdependingonthelengthoftheacid
supplytube.
 