Instruction manual

6 7
 
1. Identifyastraightsectionofhorizontalpipe
ofappropriatelengthafterthelterbut
beforethesaltcell(30cmisrecommended).
2. DisassemblesensorPODtogetlowerpart
ofPODclampwith2holes(picture1).
3. PlacethelowerpartofPODclampupside
downintopositionontheselectedlengthof
piping
4. Nowmarkthelocationofthe2holestobe
madeintopipingusingapencilormarker
(picture2).
5. Drillthe2holesusingtheprovidedhole
saw.Ensurethatholesareperfectlysmooth
aroundtheedges(picture3).
6. PositiontheupperpartofPODclampby
slidingitintothe2previouslydrilledholes
(picture4).



7. InterlockthelowerpartofPODclamponto
theupperpartalreadyinplaceonpiping.
(ifusing40mmpipeusethespacerprovided)
8. FitthePODcapontopofupperPOD
clamp,re-tlockingringandtightenrmly
usingprovidedtool.
9. InstallthepHsensorbyrmlyscrewinginto
thePODcap.
10.Connectthesensorswiththeprovided
cabletotheappropriatesocketsontheTRi
powerpack.
2
1
Ensureowarrowsarein
thecorrect
4
3
Smoothedges
Sensor
ttedin
POD
Injectiontubetted
toonewayvalve