Instruction manual
18 19
TokeepyourTRiUnitinthebestpossibleconditionitisrecommended
regularmaintenanceshouldbeperformed.
InareasthatexperiencecalciumhardnesstheTRielectrodewillbenet
fromcleaning.
Tocleanyourelectrode:
1. Switchoffthelterpumpandchlorinegenerator,closenecessaryvalves
andunplugthecellterminalcap.
2. Unscrewtheretainingringand
removetheelectrode.Ifcalcium
buildupispresent,immersethe
electrodeincellcleaningsolution
withoutimmersingtheterminals.
3. WerecommendusingZodiacSalt
ChlorinatorCellCleanertoclean
theelectrode.Howeveryoucanmix
yourownbycarefullyaddingone(1)
partofHydrochloric(Muriatic)acid
toten(10)partswater.Strongersolutionswillshortenterminallife.
4. Allowthecleaningsolutiontodissolvethecalciumdepositsforabout
10minutes.DisposeofthecleaningsolutionatanapprovedCouncil
Depotandneverintostormwaterorsewagedrains.
6. Rinsetheelectrodeincleanwaterandre-ttheelectrodeinthecell
housing.
7. Replacethecellheadandplug
assemblyandresetvalvesand
switches.TurnpumpandTRion.
8. Conrmchlorineoutputand
settingsonthepowerpack.Timer
settingswillbeautomatically
retained.