Before performing installation, disconnect all power.
Connect to a circuit that is protected by a ground fault circuit interrupter (GFCI).
Service to Zodiac equipment should only be carried out by qualied and authorized pool professionals.
Child Safety
Children should not be allowed to operate or perform maintenance on this product.
No one, particularly children, should sit, step, lean, or climb on any of your pool’s operational systems.
In the interests of child safety, all components of a pools operational system should be located at least
3,5 metres away from the pool.
Electrical Hazard
e Zodiac TRI Power pack must not come into contact with water and should be installed at least 3,5 metres
from the inside wall of your swimming pool.
Should a lack of water be detected, the units electronic ow switch is designed to turn o the system.
Interfering with the electronic ow switch could result in personal injury and/or damage to the cell.
Installation guide
e following steps will help you get up and running with your Tri salt water chlorinator.
WARNING
Your appliance must be installed by an experienced pool professional.
3.1 Installing the TRi control box
1. Find a suitable location for the control box mount. It should be installed no further than 1.8 metres from
the cell (this is the maximum cell cable length), the ideal location would be in a ltering box that is dry and
ventilated.
WARNING: If the control box is xed to a post it must have a waterproof panel ed behind the
control box which is at least 350 mm wide and 400 mm high.
2. Using the screws provided fasten the mount solidly to the wall and place the control box on it. Connect the
appliance but do not switch on the mains power.