Diagnostics menu
e Zodiac TRi chlorinator automatically warns you in the event of a problem or a fault by displaying a message on
the screen. To aid in the understanding of these error messages the appliance has an internal diagnostic aid menu.
is automatically scrolling menu helps you by giving suggestions to solve the problem.
To access the Diagnostics menu:
Press the key.
Use the keys to navigate to ‘DIAGNOSTIC’.
Press to display the error message menu.
When in the ‘ERROR MESSAGE’ menu use the keys to select the message that was displayed.
Press .
A certain number of solutions will be suggested and displayed temporarily in order of priority (automatic scrolling).
Aer the display the TRi automatically returns to the ‘DIAGNOSTIC’ menu.
To return to the operational display press . Otherwise the operational display will be shown automatically
aer about 30 seconds.
>
>
Select
Menu
Select
Menu
8
Error and warning messages: interpretation
8.1 ‘CHECK SALT’
¬
Interpretation:
e salt concentration in the pool is insucient and/or the water temperature is too low (the orange “Salt” indicator
is lits).
¬
Possible causes:
Lack of salt (< 4 g/L) due to water loss or dilution (lter backwash, change of water, rain, leakage…).
e pool water temperature is too low (< 18 °C, variable).
¬
Solutions:
- Add salt to the pool water to maintain the level at 4 g/L. If you don’t know the salt level or how to test it contact
your reseller.
- A simple case of production limitation when the water is too cold. Reduce chlorine production or add salt to
compensate.
8.2 ‘NO FLOW’
¬
Interpretation:
e ow of water in the cell is insucient or has stopped and the ow detector has stopped chlorine production
(the red “Flow” indicator is lit).
¬
Possible causes:
e ltering pump is faulty, the lter and/or skimmers need to be cleaned, the by-pass valve is closed, a wire is
disconnected…