Installation guide

35
5.4 Polaris EOS/ Jandy Aqualink controllers:
Green wire (0V) on the ‘0V’ TRi terminal
Red wire (+V) on the ‘POS’ TRi terminal
Yellow/white wire (B) on the ‘B’ TRi terminal
Black wire (A) on the ‘A’ TRi terminal
5.5 Pentair Intellitouch controllers:
Green wire to the ‘B’ TRi terminal
Red wire to the ‘POS’ TRi terminal
Yellow wire to the ‘A’ TRi terminal
Black wire to the ‘0V’ TRi terminal
5.6 Checking wiring
Once the connection between the external controller and the TRi chlorinator has been made it must be tested.
1. Turn on the external controller and the Zodiac TRi.
2. If the connection is correct the ‘Ŧsymbol will appear at the top right hand corner of the screen aer about 20 seconds.
3. If the connection is not made then turn the two appliances o and try again.
5.7 Checking connections
To check the connection:
1. Turn on the TRi and check the controller seings (follow the instructions in the ‘Seing the external controller
type’ paragraph.
2. Check the connection again.
NOTE: For safety reasons the Zodiac TRi will automatically switch o if the connection is lost.
6
Water balance
pH
Free chlorine
mg/L ou ppm
TAC
(total alkalinity)
°f (ppm)
TH
(total hardness)
°f (ppm)
Cyanuric acid
(stabiliser)
mg/L ou ppm
Salt level
g/L ou kg/m3
Accepted
standard
7.0 – 7.6 1 – 3
8 – 20
(80 – 200)
10 – 30
(100 – 300)
25 – 75 3 – 7
Recommended
values
7.2 – 7.4 1 – 2
8 – 15
(80 – 150)
10 – 30
(100 – 300)
< 50 4
To increase Add pH plus
Increase
production or
add chlorine
Add alkalinity
corrector
(“TAC+”)
Add calcium
chloride
Add
cyanuric acid
Add salt
To reduce Add pH minus
Reduce
production or
turn o the
appliance
Add
hydrochloric
acid
Add a calcium
sequesterer
or carry out
decarbonation
Partially
empty
the pool and
rell
Partially
empty
the pool and
rell
Frequency of
test (bathing
season)
Weekly Weekly Monthly Monthly Quarterly Quarterly