Specifications
6.4.1 Connection to a Remote
Pool-Off-Spa Selector (3-Wire
Connection)
6.4.1.1 Install the Remote Pool-Off-Spa
Selector
1. Turn off the power to both the pool/spa control
system and the heater unit. Refer to Figure 17.
2. Remove the front panel door from the front of the
heater to access the raceway.
3. Run the wires from the pool/spa control system
through the opening, located on the lower right or
left hand side of the heater.
4. Connect the wiring from the pool/spa control
system to the heater remote control terminal. See
Figure 17.
5. Restore power to the heater and the pool/spa
control system.
6.4.1.2 ConguretheControlPanel
1. Make sure the control is in the OFF mode.
2. To enter the Service Setup mode, press and
hold the MENU, POOL, and SPA buttons for 5
seconds.
NOTE The display will revert back to OFF after one
minute since the last key press.
3. Press the Up or Down button to display
REMOTE. Press the MENU button.The
SELECT REMOTE OFF (default remote)
appears. Use the Up or Down button to scroll
through the Remote options. When you reach HI-
LO-COM, press the MENU button to select the
remote. Press POOL or SPA to exit the Service
Setup mode.
6.4.2 Connection to an AquaLink
®
RS, PDA, Remote TSTAT (2-Wire
Connection) or Fireman's Switch
6.4.2.1 Install the Remote TSTAT
1. Turn off the power to both the pool/spa control
system and the heater unit.
2. Remove the front panel door from the front of the
heater to access the raceway.
3. Run the wires from the pool/spa control system
through the opening, located on the lower right or
left hand side of the heater.
4. Connect the wiring from the pool/spa control
system to the heater remote control terminal. See
Figure 18.
5. Restore power to the heater and the pool/spa
control system.
NOTE If you install a time clock to control the lter
pump operation, it is recommended that the
time clock have its own low voltage (Fireman’s)
switch to turn off the heater before turning off
the pump. The switch should shut off the heater
about 15 minutes before the lter pump shuts
off. This will allow for a more efcient operation
by removing any residual heat contained in the
heat exchanger back to the pool.
6.4.2.2 ConguretheControlPanel
1. Make sure the control is in the OFF mode.
2. To enter the Service Setup mode, press and
hold the MENU, POOL, and SPA buttons for 5
seconds.
Figure 17. Remote Pool-Off-Spa Connection (3-Wire
Connection)
Figure 18. AquaLink
®
RS or Remote TSTAT Connection
(2-Wire Connection)
Page 23
ENGLISH
Jandy
®
Legacy™ Model LRZE Pool/Spa Heater by Zodiac
®
|
Installation and Operation Manual