Specifications
Installation and Operation Manual 
|
 Legacy™ Model LRZM Pool/Spa Heater 
3.  A noncombustible platform for installation 
on combustible surfaces (see Section 2.5.3). 
Noncombustible bases are available from your 
Zodiac distributor.
4.  A factory approved vent cap for all outdoor 
installations where wind conditions may cause 
downdrafting. Approved vent caps are available 
from your Zodiac distributor. See Section 12.2, 
"Parts List", of this manual for the correct part 
number.
 
 
1.  Installation Location:
  Certied for use:
    Natural Gas:  Indoor and Outdoor
    LPG:    Outdoor Only
  Refer to Table 1.
2.  Minimum Clearance From Combustible Material
  See Table 4.
 
The Legacy Model LRZ millivolt heater perfor-
mance specications are shown in Table 2.
 
See Figure 1 for a diagram showing the heater's 
exterior dimensions and dimensions to critical connec-
tions on the heater.
 
This product must be installed and serviced by a 
contractor who is licensed and qualied in pool 
equipment. Improper installation or maintenance 
can cause nausea or asphyxiation from carbon 
monoxide in ue gases which could result in severe 
injury, or death. For indoor installations, as an ad-
ditional measure of safety, Zodiac strongly recom-
mends installation of suitable Carbon Monoxide 
detectors in the vicinity of this appliance and in any 
adjacent occupied spaces. The heater may only be 
installed in a room which complies with the appro-
priate ventilation requirements and which is sepa-
rate from living areas.
Install the Legacy Model LRZ millivolt heater, 
vent caps and draft hoods in accordance with the 
procedures in this manual, local codes and ordinances, 
and in accordance with the latest edition of the appro-
priate national code (see Section 1.4 "Codes and 
Standards").
All gas-red products require correct installation 
to assure safe operation. The requirements for pool 
heaters include the following:
1.  Field assembly (if required)
2.  Appropriate site location (clearances) and ooring
3.  Sufcient combustion and ventilation air
4.  Properly sized gas meter and piping
LRZ
125 175 250 325 400
Water Capacity (L) 0,81 0,95 1,16 1,35 1,57
Minimum Water Flow (l/min) 75,7 75,7 94,6 113,6 113,6
Maximum Static Head (bar) 5,1 5,1 5,1 5,1 5,1
Maximum Outlet Temp (C) 40 40 40 40 40
Dry Weight (kg) 60 67 78 88 100
Gas Connection 3/4 in Bsp
(Rc 3/4)
3/4 in Bsp
(Rc 3/4)
3/4 in Bsp
(Rc 3/4)
3/4 in Bsp
(Rc 3/4)
3/4 in Bsp
(Rc 3/4)
Water Inlet Connection 2" unthreaded PVC 
or CPVC
2" unthreaded PVC 
or CPVC
2" unthreaded PVC 
or CPVC
2" unthreaded PVC 
or CPVC
2" unthreaded PVC 
or CPVC
Water Outlet Connection 2" unthreaded PVC 
or CPVC
2" unthreaded PVC 
or CPVC
2" unthreaded PVC 
or CPVC
2" unthreaded PVC 
or CPVC
2" unthreaded PVC 
or CPVC
Electrical Supply
220-240VAC, 50 Hz, 
5 Amps Max
220-240VAC, 50 Hz, 
5 Amps Max
220-240VAC, 50 Hz, 
5 Amps Max
220-240VAC, 50 Hz, 
5 Amps Max
220-240VAC, 50 Hz, 
5 Amps Max
IP Rating IPX4
Flue Types Flue Type A (Flueless) for Outdoor Installations Only
Flue Type B11 (with Vent Cap for High Wind Areas) For Outdoor Installation Only
Flue Type B11 (with Draft Hood) for Indoor Installation Only
Appliance Category:         
Natural Gas          I2H 
LPG            I3P
Inlet Pressure (mbar)
Natural Gas  G20
LPG    G31 @ 37 mbar
Note: The LPG heat inputs apply up to an altitude of 600 m. Above this altitude, de-rate the heat input by 4% for every 300 m.