User manual
3.3 FLOW METER INSTALLATION
The flow meter and its paddle clamp (DN50 mm) must be installed on the piping close to the
Ei cell and upstream from it.
> Ei cell installed on-line: the flow meter MUST be installed right next to the cell and after
the valve (if any).
> Ei cell installed on a by-pass: The flow meter MUST be installed on the cell by-pass
between the upstream cut-off valve and the cell itself.
WARNING: Non compliance with these instructions may result in damage to the
cell (See diagrams)!
CORRECT: BAD:
IMPORTANT NOTE: The flow meter has a direction (Arrow indicating the water flow direction).
Make sure that it is properly positioned on its paddle clamp in order to stop the Ei chlorine
generator production when the filtering is not operating ('Flow' red alarm lit to be interpreted
as a lack of flow).
Once the flow meter is installed on the paddle clamp (use Teflon tape on the screw-thread to
ensure watertightness), connect the wiring to the Ei power pack using the quick 'JACK' plug.
3.4 Ei POWER PACK CONNECTION
The Ei Zodiac appliance is designed to operate only with a 220-240 Vac 50 Hz. power supply.
IMPORTANT: The installation and use of Ei salt water chlorinators must comply with the
instructions and recommendations presented in this manual. For additional information,
please contact your professional pool retailer.
The Ei chlorinator may be connected in two different ways:
> Either directly connected to the pool filtration (the appliance will only be powered during
filtration periods).
> Or permanently connected to a power supply thanks to the presence of a flow meter (Power
supply protected with a 30 mA circuit breaker).
Once the connections are completed successfully and glue (if any) has set and dried (wait
a few hours depending on the product used), connect to the electrical mains in order to
operate the Ei.
31