7/ERROR AND WARNING
MESSAGES
7.1 'CHECK SALT'
Interpretation: 
The salt concentration in the pool is insufficient and/or the water temperature is too low
(The orange 'SALT' indicator is lit).
Possible causes: 
Lack of salt (< 4 g/L) due to water loss or dilution (filter backwash, change of water, rain, leakage…).
The pool water temperature is too low (< 18 °C, variable).
Solutions:
> Add salt to the pool water to maintain the level at 4 g/L. If you don't know the salt level or
how to test it contact your pool specialist 
> A signal simply indicating limited release when the water is too cold. Reduce chlorine production
or add salt to compensate.
7.2 'NO FLOW '
Interpretation: 
The flow of water in the cell is insufficient or has stopped and the flow detector has stopped
the chlorine production (the red “Flow” indicator is lit).
Possible causes: 
The filter pump is faulty, the filter and/or skimmers need to be cleaned, the by-pass valve is
closed, a wire is disconnected. 
Solutions: 
> Check the pump, the filter and the skimmer(s). Clean them if necessary.
> Check the correct operation of the flow sensor.
> Check the wiring connections (cell and flow sensor).
7.3 'OUTPUT FAULT'
Interpretation: 
There is a problem with the internal power supply to the Ei command box.
Possible causes: 
> Cell power supply cable disconnected or incorrectly connected.
> Internal power problem in the command box following an external electrical incident.
Solutions: 
> Turn the Ei chlorinator off ( button) and cut off the power supply to the command box; 
then check that all the wires are correctly connected (mains, cell…).
> Contact your reseller.