3. Set the external clock (filtering command box) in order to programme the operating times.
4.7 SETTING CHLORINE PRODUCTION
1. Turn on the Ei chlorinator by pressing the key.
2. Press the key to adjust the level of chlorine production. The minimum release level
corresponds to the first green visual indicator (approximately 20%) and the increments (Green
visual indicators) are per additional 20% units, one at a time, up to the maximum (4 green
indicators lit simultaneously).
3. If you maintain the key pressed and exceed the maximum, the chlorine production level
will drop back to the minimum (orange indicator).
NOTE: The chlorine production level display indicates a setting and does not correspond
to the 'real' chlorine production, as it only expresses a desired level of production.
The production level corresponds to a percentage of the operating cycle, as, for
example:
> 1
st
orange indicator lit (20%) = 2 minutes of production, 8 minutes of pause
> 3 green indicators lit (80%) = 8 minutes of production, 2 minutes of pause.
36