Product specifications
Page 8
Section 2. System Description
Figure 1. Example of Installation
2.1 Product Specifi cations (APURE35 and APURE35C)
Maximum Operating Pressure: 50 psi Input Freq: 47~63 Hz
Minimum Flow Rate: 152 lpm (40 gpm) Output Voltage: 25V DC (max)
Maximum Flow Rate: 348 lpm (92 gpm) Output Current: 5A DC
Required Salt Level: 4,000 ppm (4.0 gpl) Dimensions:
Power Pack (L x W x H):
25.4 cm x 11.4 cm x 33 cm (10 in. x 4.5 in. x 13 in.)
Electrolytic Cell (L x W x H):
16.5 cm x 14 cm x 30.5 cm (6.5 in. x 5.5 in. x 12 in.)
Maximum water volume treated:
132,000 L (35,000 gal.)
Chlorine Output:
0.42 kg (0.93 lbs.) per day
Input Voltages: 240 V or 120 V
(the system
auto-detects voltage)
Weight:
Power Pack: 3.2 kg. (7 lbs)
Electrolytic Cell: 0.9 kg (2 lbs.)
Input Current @ 240 VAC: ~1 A
Input Current @ 120 VAC: ~1.3 A
The cell must be installed as the
last piece of equipment in the
circulation plumbing system just
before the pool
Cell
Heater
Pump
To common
power source
Power Pack
Filter
Pool Intake Spa Intake