Do not install
past 45 degrees
Figure 24. Example of Alternative Installation
3.9 Alternative Installation (When Pipe is Obstructed)
If the only suitable length of pipe is obstructed, such as on a multiport valve often found on a sand fi lter, it is
acceptable to ‘lean’ the cell over up to a maximum of 45 degrees (see Figure 24). Mark the feeder holes in the same
angle that the cell will be leaning to ensure that you drill in the right position.
3.8 Split Return Plumbing Instructions: For Infl oor Cleaning Systems
If the chlorinator is used with an in-fl oor cleaning system, it must be installed in a separate dedicated return line or
damage to the chlorinator will occur.
NOTE Do not install the chlorinator on in-fl oor systems that do not have a dedicated pool return as shown in Figure 23.
The cell must be installed as the
last piece of equipment in the
dedicated return plumbing just
before the pool.
Cell
To In Floor
Cleaning System
From Pump
Pool Return
Figure 23. New Pool Plumbing for In-Floor Systems