Product specifications

Page 15
3. Remove the white cap covering the comm hole (see Figure 19).
4. Thread the controller cable through the hole. A grommet may be necessary depending on the size of the cable
being used.
5. Attach a cable tie to the controller cable as shown (see Figure 19).
Cable Tie
Comm Hole
Figure 19. Accessing and Wiring to the Power PCB
6. In the AquaLink
®
RS or PDA power center, wire the power pack directly to the LOAD SIDE of the lter pump
relay
(see Figure 20).
Figure 20. Wiring Power Pack to an AquaLink RS or PDA Power Center (240 VAC and 120 VAC)
AquaLink RS or PDA Power Center
Filter Pump Relay
Aux. 3 Relay
Load
1
Line 1
120 VAC
To Filter Pump
(120 VAC)
To Power Pack
(120 VAC)
Neutral
To Breaker
Panel
Filter Pump Relay
Aux. 3 Relay
Load2
Line 2
Load1
Line 1
240 VAC
To Filter Pump
(240 VAC)
To Power Pack
(240 VAC)
To Breaker
Panel