Installation Data Power Sensor Filling PWR II Installation and Operation Manual Power SENSOR FILL Sensor II Sensor I Filling 1 Power Sensor Filling Filling II Electronic Water Levelor Model No. K-2300 Model No. LEV110CK/2G The next genera tion in automated control s.
Page 2
Page 3 Table of Contents Section 1. Safety Information....................... 4 Section 2. System Description..................... 5 2.1 2.2 Electrical Specifications................................5 Wiring Diagrams...........................................6 Section 3. Installation Instructions............ 10 3.1 3.2 3.3 3.4 3.5 3.6 3.7 Materials and Tools.....................................10 Installing the Control Box............................10 Changing Wiring for 110 Volt Operation ....
Page 4 Section 1. Safety Information IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF PROPERTY DAMAGE OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS When installing and using this equipment, basic safety precautions should always be followed, including the following: WARNING FOR YOUR SAFETY. This product must be installed and serviced by a professional service technician, qualified in pool/spa installation and maintenance.
Page 5 Section 2. System Description Fill Line Levolor® Models K-1100, LEV110CK/2G, and LX2 are computer-controlled devices that detect a low water condition and automatically replace the water to a preset level. They can be used in all pools and spas. The LEV110CK/2G is designed for use in large commercial applications. Levolor II, Model K-2300, is a dual-fill device that can maintain the water level in two (2) separate environments, such as a pool/spa combination or other dual-equipped application.
Page 6 2.2 Wiring Diagrams This section contains wiring diagrams for the K-1100, K-2300, and LEV110CK/2G, along with detailed views of the factory-direct wiring for 220 VAC and the modified wiring for 110 VAC. The section also contains a wiring diagram for the LX2, along with detailed views of the factory-direct wiring for the 220 VAC and 110 VAC units.
Page 7 220 Volt Operation Transformer BLK/YEL BLK/WHT BLK Green Ground 1 2 BLK/RED 5 6 Line 2 Line 1 Figure 4. K-1100, K-2300, and LEV110CK/2G Factory Wiring for 220 Volt Operation 110 Volt Operation Transformer Ground Line 1 BLK/YEL 2 BLK/RED 5 BLK/WHT BLK Green 6 Neutral Figure 5.
Page 8 Front Inside View Back Inside View PCB 24 VAC S1 A Connect to Blue Solenoid Valve Wires Connect to Orange Sensor Wires Transformer Case B Transformer Enclosure Black Black Green Blue Wires to Solenoid Valve High Power ½" Conduit Valve ½" Conduit Orange Wires to Sensor Power Connect to Solenoid Using Grease-Filled Wire Nuts Black Green (Ground) Black 220 VAC or White 110 VAC Black See Figure 7 for factorydirect wiring for 220 volt operation and Figure 8 for factory-direct wiring
Page 9 Five (5) Status Lights Red Wires to Filling Valve II Blue Wires to Filling Valve I Black Wire to Power (24 VAC) Yellow Wire with Red Stripe to Sensor II Yellow Wire to Sensor Common Yellow Wire with Blue Stripe to Sensor I Black Wire to Power (24 VAC) Transformer Green Wire (Ground) Black Wire Black Wire/White Stripe Black Wire/Red Stripe Black Wire/Yellow Stripe Sensor I (Yellow Wire with Blue Stripe) See Figure 4 for factory-direct wiring for 220 volt operation and Figure 5 for modified wirin
Page 10 Section 3. Installation Instructions 3.1 Materials and Tools Installation Materials Supplied for Levolor® Models K-1100, LX2, or LEV110CK/2G Qty Sensor with Wire 1 Solenoid Valve 1 Coupler 1 Control Box 1 Remote Sensor Housing 1 Hardware Kit 1 Installing the Control Box NOTE When installing a Levolor on a spa (less than 300 sq ft of surface area), turn the flow control down to reduce the flow rate of the valve.
Page 11 3.3 Changing Wiring for 110 Volt Operation WARNING Potentially high voltages in the Levolor® control box can create dangerous electrical hazards, possibly causing death, serious injury or property damage. Turn off power at the main circuit breaker providing power to the control box to disconnect the control box from the system.
Page 12 3.6 Installing the Sensor NOTE If using a dual style sensor, cut off and discard the sensor you are not planning to use. See Figure 12. CAUTION Important Safety Instructions. Sensor wires must be continuous and not spliced. Solder all low voltage wire connections when possible and always use grease-filled wire nuts on low voltage connections. 1. Install the sensor in the appropriate location for the sensor style. a. Mount the skim (half-moon) sensor horizontally to an existing skimmer.
Page 13 Anti-siphon Valve Sensor Probes House or Irrigation System Levolor® Control Box Check Valve Return to Pool Figure 15. Skim (Half-moon) Sensor in Skimmer Installation in Exisiting Pool 3.7 Installation Diagrams This section shows diagrams of skim (half-moon) style and slip style sensor installations and details.
Page 14 9" Deck Lid ½" Conduit Connection PVC Cut To Length PVC 6" 1" PVC Cut to Length 1" Coupling Sensor Conduit to Sensor Control System at Control Box Terminate Sensor at Minimum Operating Level 2" Static Line Vented at Top by Drilling Hole in It Coupling Slip Sensor Desired Water Level Figure 17. Slip Sensor Detail Figure 18. Slip Sensor in Remote Housing Detail Figure 19.
Page 15 Levolor® Electronic Water Leveler 24 VAC 1 ½" to Return Line 110 / 220 VAC Water Level Controller DO NOT OPEN 6" MIN. NO USER SERVICEABLE PARTS INSIDE Solenoid Valve From City Water Supply Via DBL CHK VLV 1" Brass "Y" Strainer Equip Room Floor Level Operating Water Level MIN. 1' - 0" Operating Water Level 2" Stilling Line NOTE Install Line Level or Run Uphill From Pool to Prevent Air Lock Figure 20.
Page 16 Section 4. Operation 4.1 Power Light Sensor Light Fill Light K-1100, LEV110CK/2G, and LX2 The controllers for the K-1100 and LEV110CK/2G (See Figure 22) and the LX2 (See Figure 23) each have three (3) lights. Refer to the figures and Table 1. Power Light PWR SENSOR FILL Sensor Light Filling Light DO NOT OPEN NO USER SERVICEABLE PARTS Power Sensor INSIDE Figure 23. LX2 Controller Lights Filling The Power light turns green when the unit is powered on.
Page 17 4.2 K-2300 The controller for the K-2300 has five (5) lights. See Figure 24 and refer to Table 2. The Power light turns green when the unit is on. The Sensor I light turns yellow when water is not touching the Sensor I tips. Twenty seconds later, the Filling I light turns green, indicating that Valve I is operational and filling. The light turns off when the pool is filled, and turns red when Valve I goes into Safety Lockout Mode.
Page 18 4.4 Fill Time before Lockout Model K-1100 and LX2: For the K-1100 and LX2 the factory-set Fill time before Safety Lockout occurs is 20 minutes. The Fill time can be modified by cutting the jumpers as follows: Cut Jumper Fill Time Period Either A or B 40 minute fill before lockout Both A and B 60 minute fill before lockout Jumper Cables S1 A B NOTE To disable the lockout feature, cut jumper S-1.
Page 19 Section 5. Troubleshooting 5.1 Manual Valve Override There is a manual ON/OFF lever located just below the solenoid. If you are having a problem with the system and want to override the electronic water Levolor®, you can manually open the valve by putting the lever in the ON position. See Figure 11. During normal operation, the lever must be in the OFF position. 5.2 b.
Page 20 5.4 Fill Will Not Turn OFF This is a troubleshooting flow chart for the K-1100, LX2, and LEV110CK/2G. Use it when the Fill function will not turn off. Fill Will Not Turn OFF Is fill light green or red? YES Is fill light on? NO RED GREEN Pull sensor out of water. Disconnect blue valve wires from control box. Does green NO fill light turn off? YES Possible Issues: 1. Needs greased-filled wire nut at valve. 2.
Page 21 5.5 Fill Will Not Turn ON This is a troubleshooting flow chart for models K-1100, LX2, and LEV110CK/2G. Use it when the Fill function will not turn on. Fill Will Not Turn ON Lockout sequence has taken effect. Call technical support (707) 776-8200 ext 260. Is power light on? NO Transformer is bad. Pull sensor out of water. YES NO Does sensor light turn on? YES Disconnect orange sensor wires at control box. Wait 20 seconds.
Page 22 Section 6. Replacement Parts 6.1 Ordering Information To order or purchase parts for the Levolor® products, contact your nearest Jandy dealer or distributor. See the Jandy website at www.jandy.com for the nearest service center. For further assistance, contact Customer Service at Zodiac Pool Systems, Inc. at (800)-822-7933. NOTE To order the correct part, you need to supply the correct model number and part number. Key Description Model No. Part No.
Page 23 Key Description Model No. Order Part No.
Limited Warranty Zodiac Pool Systems, Inc. (“Zodiac”) warrants all Baracuda®, Jandy®, Nature2® and Polaris® brand products to be free from manufacturing defects in materials and workmanship for a period of one (1) year from the date of retail purchase, with the following exceptions: 1. Jandy heat pumps are warranted for two (2) years. Heat pump compressors and heat exchangers are warranted for ve (5) years. 2. Electronic salt water chlorine generators are warranted for three (3) years. 3.