Standard IPMI Response: GetSensorReading
Byte Data Field Description
1 rqAddr 20h
2 netFn/Lun 16h
3 check1 CAh
4 rsAddr B2h
5 seq no 06
6 command 2Dh
7 completion code 00h
8 sensor reading 1Bh -> 27 Celsius degree
9 optional data
byte
C0h scanning is enabled
10 optional data
byte
C0h
11 optional data
byte
00
12 checksum2 80h
Table C.4: GetSensorResonse
Only scanning is supported and enabled for the optional bytes.