Technical data
LED Indicators
14-Slot Shelf
Chapter 2
92
Troubleshooting the Shelf Alarm Panel
The Shelf Alarm Panel is a pass-through device with no logical circuits. Problems with the SAP are generally
mechanical damage to the Telco Alarm Connector or the connector between the Shelf Alarm Panel and the
Horizontal Board.
Alarm Connector Panel Horizontal Board Connector
Figure 2-8 and Table 2-9 show the Alarm Connector Panel (ACP) Horizontal Board Connector and the pin
assignments.
Figure 2-8 Alarm Connector Panel Horizontal Board Connector
Table 2-8 Shelf Alarm Panel Troubleshooting
Tip Symptom Action
1 Communicat
ion problems
to the Shelf
thorough the
SAP
connector
1. Check Shelf Alarm Panel for proper seating and verify that the
fixing screws are tight.
2. Examine the Telco Alarm Connector for bent or broken pins. If
pins are bent or damaged, replace the Shelf Alarm Panel
Assembly.
3. Remove the Shelf Alarm Panel and examine the Shelf Alarm
Display's Horizontal Board connector for bent or broken pins. If
bent or damaged pins are discovered, replace the Shelf Alarm
Panel Assembly.
4. Examine the Shelf Alarm Panel mating connector on the
Horizontal Board for bent or broken pins. If pins are bent or
damaged, replace the Chassis.
5. Replace the Shelf Alarm Panel.
Table 2-9 Alarm Connector Panel Horizontal Board Connector Pin Assignment
Pin Signal Name Description
1 LED_USER1 Signal to User Definable LED1 on Shelf Alarm Display
2 LED_USER2 Signal to User Definable LED2 on Shelf Alarm Display