Technical data
Field Replaceable Unit Removal and Replacement
Cable Trays and Rack Mounting Flange Kit
Chapter 1
54
Cable Trays and Rack Mounting Flange Kit
This section provides procedures for removing and replacing the 14-Slot Shelf rack mount Flanges, front and
rear Cable Trays, and front and rear blade cage Filler Panels.
Removing and Replacing Rack Mount Flanges
To remove the 14-Slot Shelf rack mounting Flanges, complete the following steps:
Step 1. The rack mounting Flanges can be mounted for installing the 14-Slot Shelf in either the 4-post
equipment rack or a 2-post equipment rack (see Figure 1-14). In either case, the removal
procedures are identical.
Figure 1-14 Rack Mount Flange Positions
Step 2. Remove the two mounting flanges from the mounting position (Figure 1-14) by first removing the
two screws that secure each flange to the outside of the 14-Slot Shelf side panels.