Technical data
Field Replaceable Unit Removal and Replacement
Backplane SEEPROM Assemblies
Chapter 1
47
Removing a 14-Slot Shelf SEEPROM Assembly
WARNING Electrical Shock Hazard to Personnel. Shut down all normal operation of the 14-Slot Shelf and
disable/disconnect all external power supply power domain circuit breakers in the OFF (O)
position before completing any of the following steps. Failure to disable/disconnect all power
supplied to the 14-Slot Shelf at the power source may result in personal injury.
CAUTION Electrostatic Discharge Hazard. Observe all ESD safety precautions while completing this
procedure. Failure to follow ESD safety precautions could result in damage to the 14-Slot Shelf
and equipment.
To remove a 14-Slot Shelf SEEPROM assembly, complete the following steps:
Step 1. Remove both PEMs in order to provide maximum physical access to the defective SEEPROM.
Step 2. Carefully remove the Backplane SEEPROM Assembly fixing screw (#4, Figure 1-9) using an
applicable Torx head screw driver. Note that the Torx drive mounting screw is not captive, and can
be easily dropped inside the chassis.
Step 3. Push the SEEPROM Assembly board in the direction of the arrow in Figure 1-9 to release the
locking mechanism in the mounting slot, and remove the SEERPOM Assembly from the backplane.
Step 4. Place the SEEPROM Assembly containing the defective SEEPROM into an anti-static bag.
Replacing a 14-Slot Self SEEPROM Assembly
WARNING Electrical Shock Hazard to Personnel. Shut down all normal operation of the 14-Slot Shelf and
disable/disconnect all external power supply power domain circuit breakers in the OFF (O)
position before completing any of the following steps. Failure to disable/disconnect all power
supplied to the 14-Slot Shelf at the power source may result in personal injury.
CAUTION Electrostatic Discharge Hazard. Observe all ESD safety precautions while completing this
procedure. Failure to follow ESD safety precautions could result in damage to the 14-Slot Shelf
and equipment.
To replace a Backplane SEEPROM Assembly, complete the following steps:
Step 1. Ensure that the PEMs have been removed, and that the required SEEPROM Assembly mounting
slot is open and unobstructed (see Figure 1-9).
Step 2. Hold the replacement SEEPROM Assembly vertically by its edges so that the fixing screw hole is at
the top (in the same orientation as shown in Figure 1-9). Slide the SEEPROM Assembly into its
backplane mounting slot, as shown in Figure 1-9, so that the fixing screw hole is aligned with the
fixing screw threads on the backplane.
Step 3. Ensure that the new SEEPROM Assembly is locked in place in its mounting slot, then insert and
tighten the Torx drive mounting screw (Figure 1-9).
Step 4. Reinstall the PEMs.