Technical data

Field Replaceable Unit Removal and Replacement
HP bc2100 ATCA Server Blade
Chapter 1
41
Step 6. Place the removed blade into an anti-static bag.
Replacing an HP bc2100 ATCA Server Blade
CAUTION Electrostatic Discharge Hazard. Observe all ESD safety precautions while completing this
procedure. Failure to follow ESD safety precautions could result in damage to the 14-Slot Shelf
and equipment.
To replace an HP bc2100 ATCA Server Blade, complete the following steps:
Step 1. Ensure that the slot that the HP bc2100 ATCA Server Blade is to be installed in is empty. If a blade
cage front filler panel has been installed for that slot, loosen the two filler panel retaining screws
and remove the filler panel.
Step 2. Carefully align the HP bc2100 ATCA Server Blade in its assigned slot, and slide the blade
approximately half-way into the slot.
Step 3. Holding the two extraction levers in the fully extracted position (away from each other), carefully
slide the Blade into the slot until the backplane connectors properly mate with the 14-Slot Shelf
connectors and the blade is fully seated. A blade is fully seated when it touches the 14-Slot Shelf
case up to the extractors.
Step 4. Push the extraction levers toward each other until they are seated flat against the front panel in
order to complete the seating process, and secure the retention screws. The HP bc2100 ATCA
Server Blade will not operate unless the extraction levers are fully latched.
Step 5. The blue hot-swap LED (Figure 1-6) will be blinking or off. This completes the replacement
procedure.