Technical data
Field Replaceable Unit Removal and Replacement
HP bc2100 ATCA Server Blade
Chapter 1
39
HP bc2100 ATCA Server Blade
The HP bc2100 ATCA Server Blade is a hot-swap FRU and can be removed and replaced while the 14-Slot
Shelf is fully operational.
WARNING Electrical Shock Hazard. System power is applied to the 14-Slot Shelf at all times during this
hot-swap removal and replacement procedure. Observe all electrical safety procedures while
working on this hot-swap unit.
Removing an HP bc2100 ATCA Server Blade
CAUTION Electrostatic Discharge Hazard. Observe all ESD safety precautions while completing this
procedure. Failure to follow ESD safety precautions could result in damage to the 14-Slot Shelf
and equipment.
To remove an HP bc2100 ATCA Server Blade, complete the following steps:
Step 1. Loosen the two retention screws on the HP bc2100 ATCA Server Blade front panel.
Step 2. Simultaneously pull both HP bc2100 ATCA Server Blade extraction levers to the one-half open
(extract) position only. The blue hot-swap LED located on the HP bc2100 ATCA Server Blade front
panel (Figure 1-6) will initially illuminate in a blinking mode. When the HP bc2100 ATCA Server
Blade can be safely removed, the blue hot-swap LED will illuminate continuously.