Technical data

Field Replaceable Unit Removal and Replacement
Ethernet Switch Blade
Chapter 1
37
Figure 1-5Ethernet Switch Blade Front Panel (Lower Half), Showing Blue Hot Swap
LED
Step 3. With the blue hot-swap LED illuminated continuously, simultaneously pull both extraction
handles to the full-out extract position. This will disengage the Ethernet Switch Blade backplane
connectors from the 14-Slot Shelf chassis.
Step 4. Carefully pull the Ethernet Switch Blade out of its mounting slot.
CAUTION Possible equipment damage due to excessive heat. If the Ethernet Switch Blade will
not be immediately replaced, install a blade cage front filler panel in its place in
order to maintain cooling air plenum integrity of the Shelf.
Step 5. Place the removed blade in an anti-static bag.
Replacing an Ethernet Switch Blade
CAUTION Electrostatic Discharge Hazard. Observe all ESD safety precautions while completing this
procedure. Failure to follow ESD safety precautions could result in damage to the 14-Slot Shelf
and equipment.
To replace an Ethernet Switch Blade, complete the following steps:
Step 1. Ensure that the slot that the Ethernet Switch Blade is to be installed in is empty. If a blade cage
front filler panel has been installed for that slot, loosen the two filler panel retaining screws and
remove the filler panel.