Technical data
Field Replaceable Unit Removal and Replacement
Shelf Manager
Chapter 1
34
Shelf Manager
The 14-Slot Shelf contains two redundant Shelf Managers (ShMMs) as hot-swap FRUs. These units are
located in the lower left and right corners at the front of the Shelf, and protrude into the air intake plenum.
Both ShMMs are accessible from the outside front of the Shelf.
WARNING Potential Electrical Shock Hazard to Personnel. System power is applied to the 14-Slot Shelf at
all times during this hot-swap removal and replacement procedure. Observe all electrical
safety procedures while working on this hot-swap unit.
Removing a Shelf Manager Unit
CAUTION Electrostatic Discharge Hazard. Observe all ESD safety precautions while completing this
procedure. Failure to follow ESD safety precautions could result in damage to the 14-Slot Shelf
and equipment.
To remove a ShMM unit, complete the following steps:
Step 1. Loosen the ShMM fixing screw (#1, Figure 1-4), and pull the ShMM extraction handle
approximately one-half of its full travel distance away from the ShMM front panel. The blue
hot-swap (H/S) LED (#10, Figure 1-4) will flash intermittently as the request is being processed by
the Shelf Manager, then illuminate solid when the unit is ready to be hot-swapped (removed).
Figure 1-4Shelf Manager (ShMM) Front Panel