Technical data

Field Replaceable Unit Removal and Replacement
Power Entry Modules (PEMs) and PEM Fuses
Chapter 1
31
Figure 1-2Power Entry Module (PEM) A, Power Cables and Returns Attached
Step 3. With the blue hot-swap LED steadily illuminated and all input power disabled/disconnected,
remove the PEM Terminal Block Cover (#5, Figure 1-2.
Step 4. Remove and label each terminal block power and return cable for replacement hookup.
Step 5. Loosen both PEM fixing screws (#7, Figure 1-2).
Step 6. Using the two PEM handles (#6, Figure 1-2), pull the PEM from its mounting slot.
Step 7. Place the removed PEM in an anti-static bag for shipment.
Replacing a Power Entry Module
CAUTION Electrostatic Discharge Hazard. Observe all ESD safety precautions while completing this
procedure. Failure to follow ESD safety precautions could result in damage to the 14-Slot Shelf
and equipment.
To replace the PEM in the Shelf, complete the following steps:
Step 1. Holding the replacement PEM by its handles (#7, Figure 1-2) carefully insert the PEM into the
empty PEM slot. Ensure that the PEM internal electrical connectors are aligned, and then use firm
pressure to ensure that the PEM is properly seated in the connector.
Step 2. Tighten the PEM fixing screws that hold the PEM in the 14-Slot Shelf chassis (#7, Figure 1-2).