Technical data

Field Replaceable Unit Removal and Replacement
Safety and Environmental Considerations
Chapter 1
27
Safety and Environmental Considerations
Safety and environmental considerations include electrical safety, communications interference, and
electrostatic discharge hazards to equipment.
Electrical Safety
Electrical safety precautions must be followed at all times when working on the 14-Slot Shelf.
WARNING High Voltage. There are no system power controls on the 14-Slot Shelf. System power (-48 VDC
from multiple power domains) is applied by an external power source at all times unless
disabled/disconnected at the source.
Communications Interference
Hewlett-Packard system compliance tests are conducted with Hewlett-Packard supported peripheral devices
and shielded cables, such as those received with the system. The system meets interference requirements of
all the countries in which it is sold. These requirements provide reasonable protection against interference
with radio and television communications.
Installing and using the system in strict accordance with Hewlett-Packard instructions minimizes the
chances that the system will cause radio or television interference. However, Hewlett-Packard does not
guarantee that the system will not interfere with radio and television reception.
Take these precautions:
Use only shielded cables.
Ensure that all cable connector screws are firmly tightened.
Use only Hewlett-Packard supported peripheral devices.
Ensure that all panels and cover plates are in place and secure before system operation.
Electrostatic Discharge Hazard to Equipment
Hewlett-Packard systems and peripherals contain assemblies and components that are sensitive to
electrostatic discharge (ESD). Carefully observe the precautions and recommended procedures in this manual
to prevent component damage from static electricity.
CAUTION Wear an ESD wrist strap that is connected to the same ground potential as the unit you are
working on. Connect the wrist strap to any grounded metal assembly in the 14-Slot Shelf or to
one of the ESD grounding sockets (see Figure 1-1). Both you and the electronic devices must be
grounded to avoid static discharges that can cause damage. If the 14-Slot Shelf is not connected
to earth ground, place the Shelf in an ESD-safe working environment before removing or
replacing any FRU.