Technical data
Field Replaceable Unit Removal and Replacement
Power-Off Field Replaceable Units
Chapter 1
25
Power-Off Field Replaceable Units
Field Replaceable Units are considered to be power-off FRUs if electrical power must first be removed from
the 14-Slot Shelf before the FRU can be removed and replaced. Power-off FRUs in the 14-Slot Shelf include
the following:
• HP 14-slot 14-Slot Shelf Chassis with Backplane
• Backplane SEEPROM Assembly (Chassis Data Module)
The following FRUs are power-off FRUs, but are removed and replaced after the HP bc2100 ATCA Server
Blade has been removed from the 14-Slot Shelf by following hot-swap procedures:
• HP 72 GB SAS Hard Disk Drive (HDD) – HP bc2100 ATCA Server Blade
• HP 72 GB SAS HDD Mounting Kit – HP bc2100 ATCA Server Blade
• 1 GB Memory DIMMs (replaced in pairs) – HP bc2100 ATCA Server Blade
• 2 GB Memory DIMMs (replaced in pairs) – HP bc2100 ATCA Server Blade