Technical data
Chapter 4
System Event Log Decoding
Sensor Type Codes (Table 36-3 from the IPMI v1.5 Documentation)
213
Slot /
Connector
21h 00h
01h
02h
03h
04h
05h
06h
07h
08h
Fault Status asserted
Identify Status asserted
Slot / Connector Device installed/attached
[This can include dock events]
Slot / Connector Ready for Device Installation - Typically,
this means that the slot power is off. The Ready for
Installation, Ready for Removal, and Slot Power states can
transition together, depending on the slot implementation.
Slot/Connector Ready for Device Removal
Slot Power is Off
Slot / Connector Device Removal Request - This is typically
connected to a switch that becomes asserted to request
removal of the device)
Interlock asserted - This is typically connected to a switch
that mechanically enables/disables power to the slot, or
locks the slot in the ‘Ready for Installation / Ready for
Removal states’ - depending on the slot implementation.
The asserted state indicates that the lock-out is active.
Slot is Disabled
The Event Data 2 & 3 fields can be used to provide an event
extension code, with the following definition:
Event Data 2
7 reserved
6:0 Slot/Connector Type
0 PCI
1 Drive Array
2 External Peripheral Connector
3 Docking
4 other standard internal expansion slot
5 slot associated with entity specified by Entity ID for
sensor
all other = reserved
Event Data 3
7:0 Slot/Connector Number
Table 4-5 Sensor Type Codes (Table 36-3 from the IPMI v1.5 Document)
Sensor Type
Sensor
Type
Code
Sensor
Specific
Offset
(Data 1)
Event