Technical data

Chapter 4
System Event Log Decoding
Sensor Type Codes (Table 36-3 from the IPMI v1.5 Documentation)
206
Power Supply 08h 00h
01h
02h
03h
04h
05h
Presence detected
Power Supply Failure detected
Predictive Failure
Power Supply AC lost
AC lost or out-of-range
AC out-of-range, but present
Power Unit 09h 00h
01h
02h
03h
04h
05h
06h
07h
Power Off / Power Down
Power Cycle
240VA Power Down
Interlock Power Down
AC lost
Soft Power Control Failure (unit did not respond to a
request to turn on)
Power Unit Failure detected
Predictive Failure
Cooling Device 0Ah - -
Other
Units-based
Senor (per
units given in
SDR)
0Bh - -
Memory 0Ch 00h
01h
02h
03h
04h
05h
Correctable ECC / other correctable memory error
Uncorrectable ECC / other uncorrectable memory error
Parity
Memory Scrub Failed (stuck bit)
Memory Device Disabled
Correctable ECC / other correctable memory error logging
limit reached
The Event Data 3 field for this command can be used to
provide an event extension code, with the following
definition:
7:0 DIMM/SIMM/RIMM identification, relative to the entity
that the sensor is associated with (if SDR provided for this
sensor)
Drive Slot
(Bay)
0Dh - -
Table 4-5 Sensor Type Codes (Table 36-3 from the IPMI v1.5 Document)
Sensor Type
Sensor
Type
Code
Sensor
Specific
Offset
(Data 1)
Event