Technical data

Chapter 4
System Event Log Decoding
Sensor Type Codes (Table 36-3 from the IPMI v1.5 Documentation)
205
Sensor Type Codes (Table 36-3 from the IPMI v1.5 Documentation)
Table 4-5 Sensor Type Codes (Table 36-3 from the IPMI v1.5 Document)
Sensor Type
Sensor
Type
Code
Sensor
Specific
Offset
(Data 1)
Event
reserved
00h - Reserved
Temperature
01h - Temperature
Voltage 02h - Voltage
Current 03h - Current
Fan 04h - Fan
Physical
Security
(Chassis
Intrusion)
05h 00h
01h
02h
03h
04h
05h
06h
General Chassis Intrusion
Drive Bay intrusion
I/O Card area intrusion
Server area intrusion
LAN Leash Lost (the system is unplugged from the LAN)
Unauthorized dock/undock
FAN area intrusion (supports detection of hot plug fan
tampering)
Platform
Security
Violation
Attempt
06h 00h
01h
02h
03h
04h
05h
Secure Mode (Front Panel Lockout) Violation attempt
Pre-boot Password Violation - user password
Pre-boot Password Violation attempt - setup password
Pre-boot Password Violation - network boot password
Other pre-boot Password Violation
Out-of-band Access Password Violation
Server
(Processor)
07h 00h
01h
02h
03h
04h
05h
06h
07h
08h
09h
IERR
Thermal Trip
FRB1/BIST failure
FRB2/Hang in POST failure (used hang is believed to be
due or related to a server failure. Use System Firmware
Progress sensor for other BIOS hangs.)
FRB3/Server Startup/Initialization failure (CPU didn’t
start)
Configuration Error
SM BIOS ‘Un-correctable CPU-complex Error’
Server Presence detected
Server disabled
Terminator Presence Detected