Technical data
Chapter 3
Diagnostics
General ATCA Diagnostics for the Shelf Management Module (ShMM)
129
• BDSelGrounded <slot number> 1/0 (1 means Enabled, 0 means Disabled)
• PwrCapability <addr> <fru_id> <Watts>
• PwrDelay <addr> <fru_id> <10ths_of_second>
• Allowance <seconds>
• PwrReorder <addr1> <fru_id1> before/after <addr2> <fru_id2>
• info_refresh
• info_force_update
showunhealthy
The showunhealthy command displays information on failing or substandard FRUs in the system. It lists all
FRUs that are reporting an unhealthy condition such as FRUs that have temperature or power problems, or
FRUs that have lost connectivity to the ShMM.
CLI> showunhealthy
12: FRU # 0 (Controller)
Hot Swap State: M7 (Communication Lost), Previous: M4 (Active), Last State Change
Cause: Unknown (0xf)
8c: FRU # 0 (Controller)
Hot Swap State: M7 (Communication Lost), Previous: M4 (Active), Last State Change
Cause: Unknown (0xf)