0x0089: Event: at Jan 10 02:12:33 1970; from:(0x88,0,0); sensor:(0x22,14);
event:0x6f(asserted): 0x0C 0xFF 0xFF
0x008A: Event: at Jan 10 04:30:24 1970; from:(0x88,0,0); sensor:(0x1b,10);
event:0x3(asserted): 0x01 0xFF 0xFF
0x008B: Event: at Jan 10 04:30:29 1970; from:(0x88,0,0); sensor:(0x1b,10);
event:0x3(asserted): 0x00 0xFF 0xFF
0x008C: Event: at Jan 10 04:30:29 1970; from:(0x88,0,0); sensor:(0x22,14);
event:0x6f(asserted): 0x0C 0xFF 0xFF
0x008D: Event: at Jan 10 20:58:41 1970; from:(0x88,0,0); sensor:(0x1b,10);
event:0x3(asserted): 0x01 0xFF 0xFF
sensor [<addr> [[lun:]<sensor id>]
The sensor command displays information about a sensor. Sensors include power and temperature sensors.
Running the command with no arguments shows information for all sensors in the system. The sensor
command is used in conjunction with the sel command to analyze SEL failures. For example:
CLI> sel –v
0x000C: Event: at: Aug 16 05:26:28 2005; from IPM Controller: 0x8c, LUN: 0,
Channel: 0
"System Firmware Progress (formerly POST Error)" (0x0f) sensor # 6
"Sensor-specific" (0x6f) event Asserted
"System Firmware Progress"
Sensor specific code 1: 0x13
0x000D: Event: at: Aug 16 05:26:28 2005; from IPM Controller: 0x8c, LUN: 0,
Channel: 0
"System Firmware Progress (formerly POST Error)" (0x0f) sensor # 6
"Sensor-specific" (0x6f) event Asserted
"System Firmware Progress"
Sensor specific code 1: 0x13
In this example, the failures show that IPM controlled 0x8c, sensor 6, is reporting problems. This is a System
Firmware progress sensor, as stated in the text. Using the sensor command gives additional information on
the failure.
CLI> sensor –v 8c 6
8c: LUN: 0, Sensor # 6 ("Sys FW Progress")
Type: Discrete (0x6f), "System Firmware Progress (formerly POST Error)"
(0x0f)
Belongs to entity: (0xa0, 97) [FRU # 0]