Technical data

Chapter 3
Diagnostics
General ATCA Diagnostics for the Shelf Management Module (ShMM)
125
Manufacturer Name = ZNYX Networks
Product Name = ZX7120-HP
Product Part / Model# = 700-0174-002
Product Version =
Product Serial Number = 01CS00111HWP
Asset Tag =
FRU Programmer File ID = 03
Multi Record Area:
PICMG Board Point-to-Point Connectivity Record (ID=0x14)
Version = 0
PICMG Board Point-to-Point Connectivity Record (ID=0x14)
Version = 0
CLI>
frucontrol <addr> <fru_id> <command>
The frucontrol command sends commands directly to a FRU. The commands available are:
cold_reset
warm_reset
graceful_reboot
diagnostic_interrupt
CLI> frucontrol 88 0 graceful_reboot
FRU Control: Controller 0x88, FRU ID # 0, command 0x02, status 204(0xcc)
getthreshold <addr> [lun:][sensor #]
The getthreshold command reads or sets sensor thresholds. For temperature sensors,
getthreshold returns information about the current temperature and can set the
critical threshold.
NOTE Use the sensor command first to locate the sensors before using these commands.
CLI> getthreshold 82 0:11
82: LUN: 0, Sensor # 11 ("Top Temp")