Technical data
LED Indicators
HP bc2100 ATCA Server Blade
Chapter 2
116
Off Red - 3
-- Red4
Table 2-33 HP bc2100 ATCA Server Blade LED Tips
Tip Symptom Action
1 No Power 1. Examine other blades in the front card cage. If all
Blades indicate no power, verify that the power is
applied to the chassis and the Power Entry Modules are
operational
2. Verify that the Server Blade s is fully inserted into the
front card cage. If not, fully seat the blade.
3. Verify that the lower ejector level is fully closed. If the
lever is open or partially open, fully close the lower
ejector lever.
4. Remove the Server Blade its backplane connectors,
especially the blue power connector, for bent or broken
pins. If any pins are bent or broken, replace the Server
Blade.
5. Examine the backplane's blade connectors for bent or
broken pins. If any pins are bent or broken, replace the
chassis.
2 Hot Swap Ejector open 1. Verify that the lower ejector handle is fully closed. The
hot swap LED may remain illuminated or blinking if it
is waiting to activate from the Shelf Manager.
2. If either ejector handle cannot be closed, replace the
Server Blade.
3. If the lower hot swap handle is closed, retrieve the
Mstate information from the Shelf Manager.
4. A blinking Hot Swap LED may indicate a failure in
communications between the Server Blade and the
Shelf Manager. Use information in the System Event
Log (SEL) to identify chassis communication problems.
If other FRUs are also encountering difficulty, replace
the Chassis.
Table 2-32 HP bc2100 ATCA Server Blade LED States (Continued)
Hot Swap
(Blue)
Healthy
(Red /
Green)
Out of
Service
(Red)
Tip